Implantable atrial defibrillator with a single-pass dual-electrode lead.
نویسندگان
چکیده
OBJECTIVES We examined the feasibility and efficacy of using a single-pass, dual-electrode (Solo) lead for atrial fibrillation (AF) detection and defibrillation. BACKGROUND The efficacy and safety of an implantable atrial defibrillator (IAD) has been extensively studied; however, separate right atrial (RA) and coronary sinus (CS) defibrillation leads are used for the present system. METHODS We studied the use of the Solo lead for AF detection and defibrillation in 17 patients who underwent cardioversion of chronic AF. The Solo lead with a proximal 6-cm RA electrode and a distal 6-cm spiral-shaped CS electrode were positioned into the CS with the RA electrode against the anterolateral RA wall. The RA-CS electrogram signal amplitudes were measured and the efficacy of the Solo lead for AF detection and defibrillation was assessed by using an external version of the IAD. RESULTS The leads were inserted in all patients without complication (mean fluoroscopy time: 13.3+/-6.8 min). The mean RA-CS signal amplitude was 484+/-229 microV during sinus rhythm and 274+/-88 microV during AF (p < 0.05). All patients had satisfactory atrial signal amplitude to allow accurate detection of sinus rhythm. Successful cardioversion was achieved in 16/17 (94%) patients with an atrial defibrillation threshold of 320+/-70 V (5.5+/-2.7 J). Insufficient interelectrode spacing resulted in suboptimal electrode locations, associated with a lower atrial signal amplitude, a higher atrial defibrillation threshold and diaphragmatic stimulation. CONCLUSIONS These results suggest a simplified lead configuration with optimal interelectrode spacing can be used with an IAD for AF detection and defibrillation.
منابع مشابه
"Two for the Price of One": A Single-Lead Implantable Cardioverter-Defibrillator System with a Floating Atrial Dipole.
In patients known to be a high risk for sudden cardiac arrest, implantable cardioverter defibrillators (ICD) are a proven therapy to reduce risk of death. However, in patients without conventional indications for pacing, the optimal strategy for type of device, dual- versus single-chamber, remains debatable. The benefit of prophylactic pacing in this category of patients has never been document...
متن کاملRadiofrequency ablation–assisted extraction of a pacing lead fragment
Case Report A 71-year-old man with ischemic cardiomyopathy and prior coronary artery bypass grafting surgery with a dual-chamber implantable cardioverter-defibrillator (ICD) placed 4 years earlier for a history of ventricular tachycardia was referred for lead extraction because of recurrent fever, vegetations on his atrial lead, and Kocuria varians bacteremia. He had a Guidant 4470 right atrial...
متن کاملDual‐chamber implantable cardioverter–defibrillator. Is it useful in patient with permanent atrial fibrillation?
In patients with permanent atrial fibrillation (AF) and implantable cardioverter-defibrillator (ICD) implant indication, a single-chamber device is the choice because AF does not provide interesting information for the treatment. It is very unusual to find patients with permanent AF that coexist with atrial tachycardia with various degree of Atrioventricular block.
متن کاملOutcomes of single- or dual-chamber implantable cardioverter defibrillator systems in Japanese patients
BACKGROUND There are no criteria for selecting single- or dual-chamber implantable cardioverter defibrillators (ICDs) in patients without a pacing indication. Recent reports showed no benefit of the dual-chamber system despite its preference in the United States. As data on ICD selection and respective outcomes in Japanese patients are scarce, we investigated trends regarding single- and dual-c...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 33 7 شماره
صفحات -
تاریخ انتشار 1999