Further comments on the measurement of carotid stenosis from angiograms. North American Symptomatic Carotid Endarterectomy Trial (NASCET) Group.

نویسندگان

  • M Eliasziw
  • R F Smith
  • N Singh
  • D W Holdsworth
  • A J Fox
  • H J Barnett
چکیده

BACKGROUND AND PURPOSE Three different methods for estimating the percentage of reduction in the diameter of the internal carotid artery (ie, stenosis) have been proposed in the literature. Further comparisons of the methods were carried out with the intent of recommending a current standard for determining the percentage of stenosis from angiograms. METHODS Angiograms from 112 patients were obtained. For each angiogram, stenosis was estimated in the manner of the European Carotid Surgery Trial (ECST method), the North American Symptomatic Carotid Endarterectomy Trial (NASCET method), and by a method using the common carotid artery lumen diameter (CC method). RESULTS Although there is much discrepancy among the estimates of stenosis arising from the three different methods for any particular patient, it is possible to predict (on average) the percentage of stenosis from one method to another. The relationship between the NASCET and CC methods is linear, with a mean ratio of distal internal carotid artery to common carotid diameter of 0.62 (SD of 0.11). The variability in the diameter of the common carotid artery lumen stabilizes only beyond 2.5 common carotid diameter units (approximately 20 to 30 mm by conventional angiography) proximal to the bifurcation. Unexpectedly, the relationships between both the ECST and NASCET methods and ECST and CC methods were parabolic (P < .001). The reasons underlying these departures from linearity are uncertain. CONCLUSIONS The comparability of our results with those reported in the literature regarding the CC and NASCET methods provides further evidence of the reproducibility of methods measuring anatomic features that can be visualized on an angiogram. Disease of the internal carotid artery is one of the important causes of ischemic symptoms. Measuring the narrowest portion of the internal artery relative to the normal portion of the same artery, well beyond the bulb, is a logical method. Moreover, benefits of carotid endarterectomy for patients with 70% to 99% stenosis as determined by the NASCET method have been well established in a clinical trial. Converting from the NASCET method to the CC method, given that the CC method is neither superior nor easier to calculate, is not recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Further Comments on the Measurement of Carotid Stenosis From Angiograms

Background and Purpose Three different methods for estimating the percentage of reduction in the diameter of the internal carotid artery (ie, stenosis) have been proposed in the literature. Further comparisons of the methods were carried out with the intent of recommending a current standard for determining the percentage of stenosis from angiograms. Methods Angiograms from 112 patients were ob...

متن کامل

Equivalence of Measurements of Carotid Stenosis A Comparison of Three Methods on 1001 Angiograms

Background and Purpose There is confusion about how carotid stenosis should be measured on angiograms. If the results of research based on different methods of measurement of stenosis are to be discussed and the results of clinical trials properly applied to routine clinical practice, measurements made by the different methods must be formally compared. Methods The method of measurement of sten...

متن کامل

Primary Findings From Selected Recent National Institute of Neurological Disorders and Stroke-Sponsored Clinical Trials That Have shaped Modern Stroke Prevention

NORTH AMERICAN SYMPTOMATIC CAROTID ENDARTERECTOMY TRIAL The North American Symptomatic Carotid Endarterectomy Trial (NASCET) answered practical questions relating to the efficacy and safety of carotid endarterectomy based on degree of carotid stenosis and accompanying medical comorbidity in patients with symptomatic carotid stenosis (The Canadian Cooperative Study Group, 1998; North American Sy...

متن کامل

Measuring carotid stenosis.

Background and Purpose: Data from recent multicenter carotid endarterectomy trials have questioned the validity and reliability of Doppler ultrasound in the assessment of carotid stenosis. Methods: We prospectively analyzed 45 patients undergoing carotid angiography to compare the North American Symptomatic Carotid Endarterectomy Trial (NASCET) and European Carotid Surgery Trial (ECST) methods ...

متن کامل

Prognostic Value and Reproducibility of Measurements of Carotid Stenosis A Comparison of Three Methods on 1001 Angiograms

Background and Purpose The use of three methods of measuring carotid stenosis, which produce different values on the same angiograms, has caused confusion and reduced the generalizability of the results of research. If the results of future studies are to be properly applied to clinical practice, and if noninvasive methods of imaging are to be properly validated against angiography, a single, s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 25 12  شماره 

صفحات  -

تاریخ انتشار 1994