Optical density filters modeling media opacities cause decreased SD-OCT retinal layer thickness measurements with inter- and intra-individual variation.

نویسندگان

  • Stanley Darma
  • Pauline H B Kok
  • Thomas J T P van den Berg
  • Michael D Abràmoff
  • Dirk J Faber
  • Caroline A Hulsman
  • Frank Zantvoord
  • Maarten P Mourits
  • Reinier O Schlingemann
  • Frank D Verbraak
چکیده

PURPOSE To assess the effect of media opacities on thickness measurements of the peripapillary retinal nerve fibre layer (pRNFL) and macular inner retinal layer (mIRL) performed with spectral-domain optical coherence tomography (SD-OCT) using a set of filters with known optical density. METHODS Spectral-domain optical coherence tomography volume scans of the optic disc and the macular area were performed in 18 healthy volunteers, using Topcon-3DOCT-1000 Mark II. A set of five filters with optical density ranging from 0.04 to 0.69 was used. The correlation was calculated between the percentage change in thickness measurements (%ΔpRNFL and %ΔmIRL) and the change in optical density. All scans and measurements were performed in duplicate by one operator. RESULTS Eighteen right eyes of 18 healthy volunteers were included in this study. Percentage decrease in pRNFL and mIRL thickness correlated with change in optical density (Spearman's rho r = 0.82; p < 0.001 and r = 0.89; p < 0.001, respectively). The measured decrease in pRNFL thickness differed from the decrease in mIRL thickness, not only between individuals, but also within the same individual. CONCLUSIONS Optical coherence tomography thickness measurements of both pRNFL and mIRL are influenced by image degradation caused by optical density filters as a model for media opacities. An underestimation of the thickness of these layers was observed, caused by a shift of retinal layer boundary placement due to image quality loss. This underestimation is not the same for each individual and also differed between the pRNFL and mIRL thickness measurements. These individual and interindividual differences demonstrate that an individual approach will be necessary to correct for this underestimation per layer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeatability of Foveal Measurements Using Spectralis Optical Coherence Tomography Segmentation Software

PURPOSE To investigate repeatability and reproducibility of thickness of eight individual retinal layers at axial and lateral foveal locations, as well as foveal width, measured from Spectralis spectral domain optical coherence tomography (SD-OCT) scans using newly available retinal layer segmentation software. METHODS High-resolution SD-OCT scans were acquired for 40 eyes of 40 young healthy...

متن کامل

Repeatability and Reproducibility of Eight Macular Intra-Retinal Layer Thicknesses Determined by an Automated Segmentation Algorithm Using Two SD-OCT Instruments

PURPOSE To evaluate the repeatability, reproducibility, and agreement of thickness profile measurements of eight intra-retinal layers determined by an automated algorithm applied to optical coherence tomography (OCT) images from two different instruments. METHODS Twenty normal subjects (12 males, 8 females; 24 to 32 years old) were enrolled. Imaging was performed with a custom built ultra-hig...

متن کامل

Reproducibility of Optical Coherence Tomography Retinal Nerve Fiber Layer Thickness Measurements Before and After Pupil Dilation

PURPOSE To evaluate the intra- and interobserver reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness measurements before and after pupil dilation using spectral-domain optical coherence tomography (SD-OCT). METHODS In this observational case series, 44 eyes of 44 healthy subjects were scanned by two trained operators on the same day, using Cirrus SD-OCT (Carl Zeiss Med...

متن کامل

Reproducibility of high-resolution optical coherence tomography in multiple sclerosis.

Optical coherence tomography (OCT) is a non-invasive method to quantify neurodegeneration as an outcome in multiple sclerosis clinical trials; however, no data exist on Cirrus spectral domain optical coherence tomography (SD-OCT) reproducibility in patients with multiple sclerosis. The objective of this study was to determine the protocol for achieving optimal inter-visit, inter-rater, and intr...

متن کامل

Effect of Media Opacity on Retinal Nerve Fiber Layer Thickness Measurements by Optical Coherence Tomography

PURPOSE To assess the effect of ocular media opacity on retinal nerve fiber layer (RNFL) thickness measurements by optical coherence tomography (OCT). METHODS In this prospective, non-randomized clinical study, ocular examinations and OCT measurements were performed on 77 cataract patients, 80 laser refractive surgery patients and 90 patients whose signal strength on OCT was different on two ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta ophthalmologica

دوره 93 4  شماره 

صفحات  -

تاریخ انتشار 2015