Thermoluminescence solid-state nanodosimetry--the peak 5A/5 dosemeter.
نویسندگان
چکیده
The shape of composite peak 5 in the glow curve of LiF:Mg,Ti (TLD-100) following (90)Sr/(90)Y beta irradiation, previously demonstrated to be dependent on the cooling rate used in the 400°C pre-irradiation anneal, is shown to be dependent on ionisation density in both naturally cooled and slow-cooled samples. Following heavy-charged particle high-ionisation density (HID) irradiation, the temperature of composite peak 5 decreases by ∼5°C and the peak becomes broader. This behaviour is attributed to an increase in the relative intensity of peak 5a (a low-temperature satellite of peak 5). The relative intensity of peak 5a is estimated using a computerised glow curve deconvolution code based on first-order kinetics. The analysis uses kinetic parameters for peaks 4 and 5 determined from ancillary measurements resulting in nearly 'single-glow peak' curves for both the peaks. In the slow-cooled samples, owing to the increased relative intensity of peak 5a compared with the naturally cooled samples, the precision of the measurement of the 5a/5 intensity ratio is found to be ∼15% (1 SD) compared with ∼25% for the naturally cooled samples. The ratio of peak 5a/5 in the slow-cooled samples is found to increase systematically and gradually through a variety of radiation fields from a minimum value of 0.13±0.02 for (90)Sr/(90)Y low-ionisation density irradiations to a maximum value of ∼0.8 for 20 MeV Cu and I ion HID irradiations. Irradiation by low-energy electrons of energy 0.1-1.5 keV results in values between 1.27 and 0.95, respectively. The increasing values of the ratio of peak 5a/5 with increasing ionisation density demonstrate the viability of the concept of the peak 5a/5 nanodosemeter and its potential in the measurement of average ionisation density in a 'nanoscopic' mass containing the trapping centre/luminescent centre spatially correlated molecule giving rise to composite peak 5.
منابع مشابه
Towards Quasi-biological Nanodosimetry
The increasing utilization of charged particle beams for therapeutic purposes requires designing novel detector systems which shall be capable of assessing radiation quality for a diversity of ion species. It is shown that the pattern of energy deposition in thermoluminescent phosphors and biological tissue contains conceptual parallels. The correlation of physical and radiobiological parameter...
متن کاملLocalized transitions in the thermoluminescence of LiF : Mg,Ti: potential for nanoscale dosimetry
We describe the effect of nanoscale spatially coupled trapping centre (TC)–luminescent centre (LC) pairs on the thermoluminescence (TL) properties of LiF : Mg,Ti. It is shown that glow peak 5a (a low-temperature satellite of the major glow peak 5) arises from localized electron–hole (e–h) recombination in a TC–LC pair believed to be based on Mg–Livac trimers (the TCs) coupled to Ti(OH)n molecul...
متن کاملEffect of UV Irradiation on Thermoluminescence Properties of Perovskite Structured Pure and Europium Doped Barium Zirconium Titanate
The BaZrxTi1-xO3: Eu 3+ phosphors have been synthesized the conventional solid state reaction method. Mechanoluminescence (ML) and thermoluminescence (TL) in barium zirconium titanate (BZT) system with Europium as dopant is reported for the first time. The BZT system belongs to perovskite family. The samples are prepared in a high temperature furnace at a temperature of 1200 o C. The powder X r...
متن کاملA TLD-based personal dosemeter system for aircrew monitoring.
Evaluation of LiF:Mg,Ti thermoluminescence dosemeters (TLDs) according to the high-temperature ratio (HTR) method enables the determination of the dose-average linear energy transfer (LET), the mean quality factor and the dose equivalent in mixed radiation fields of unknown composition. The neutron contribution is assessed by the Extended Pair method calibrated in the CERN-EU High-Energy Refere...
متن کاملInfluence of dosemeter position for the assessment of eye lens dose during interventional cardiology.
The equivalent dose limit for the eye lens for occupational exposure recommended by the ICRP has been reduced to 20 mSv y(-1) averaged over defined periods of 5 y, with no single year exceeding 50 mSv. The compliance with this new requirement could not be easy in some workplace such as interventional radiology and cardiology. The aim of this study is to evaluate different possible approaches in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 143 2-4 شماره
صفحات -
تاریخ انتشار 2011