Isometric Unilateral Bench Press

نویسندگان

  • DOUGLAS FIORANELLI
  • MATTHEW LEE
چکیده

The purpose of this study was to examine the influence of two different bar diameters on neuromuscular activation and strength. The bar diameters used reflected a standard Olympic bar (28 mm (1.1 inch); THIN) and a larger fat bar (51 mm [2 inch]; THICK). Eighteen healthy men (age 25.06 1 years) were assessed for their maximal voluntary contraction (MVC) during a unilateral isometric bench press exercise with the 2 bar types at 2 different joint angles (angle 1 and angle 2; elbow joint at ~45 and 90 , respectively). Additionally, on a separate day, subjects performed three 10-second isometric repetitions at an intensity of 80% MVC using the 2 different bars at angle 1 and angle 2. Electromyographic recordings were collected in the pectoralis major and the muscles of the forearm flexor region at a sampling rate of 1000 Hz during the second day of testing. Analysis of variance was used to examine differences in MVC between bars and also examine between bar differences in electromyographic activity for each muscle group at each joint angle. A significance level of 0.05 was used for all tests. MVC was not different between bar types, although there was a main effect of joint angle on MVC such that it was greater at angle 2. There was a main effect of bar at both angles for the forearm muscles and at angle 1 for the pectoralis such that electromyographic activity was greater with THIN. Our data do not support the hypothesis that bar diameter influences performance during an isometric bench press exercise. However, higher electromyographic activity with THIN suggests greater neuromuscular activation with a standard Olympic bar as opposed to a larger diameter ‘‘fat’’ bar. Although our data do not support the use of a fat bar for increasing neuromuscular activation, these findings should be confirmed in other resistance training exercises.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation and Reliability of a Novel Test of Upper Body Isometric Strength

The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on t...

متن کامل

Differences in unilateral chest press muscle activation and kinematics on a stable versus unstable surface while holding one versus two dumbbells

Training the bench press exercise on a traditional flat bench does not induce a level of instability as seen in sport movements and activities of daily living. Twenty participants were recruited to test two forms of instability: using one dumbbell rather than two and lifting on the COR bench compared to a flat bench. Electromyography (EMG) amplitudes of the pectoralis major, middle trapezius, e...

متن کامل

The influence of isometric preload on power expressed during bench press in strength-trained men.

The purpose of this study was to compare the power expressed during the bench press exercise in resistance-trained men following different pre-activation conditions. Twenty-two trained men (age 24.1 ± 1.7 years, height 178.6 ± 6.1 cm, body mass 81.1 ± 10.6 kg) completed a maximal effort bench press (1-RM) test (100.0 kg ± 8.1 kg). In a subsequent assessment, each participant performed concentri...

متن کامل

مقایسه فعالیت میوالکتریکی منتخبی از عضلات اندام فوقانی هنگام اجرای پرس سینه در دو روش تمرینی تی آر ایکس و پرس سینه نیمکت با هالتر

Objective: The aim of present research is to compare the myoelectric activity of some chosen upper extremity muscles while doing bench press in two training methods of TRX and barbell bench press. Methods: Ten physically healthy students of physical education with experience in TRX participated in the study. Electromyography Bio Vision sixteen-channel and surface electrodes were used to calcul...

متن کامل

Correct, fake and absent pre-information does not affect the occurrence and magnitude of the bilateral force deficit.

The present study examined whether different pre-information conditions could lead to a volitional modulation of the occurrence and magnitude of the bilateral force deficit (BFD) during isometric leg press. Twenty trained male adults (age: 24.5 ± 1.7 years; weight: 77.5 ± 7.1 kg; height: 1.81 ± 0.05 m) were examined on three days within a week. Isometric leg press was performed on a negatively ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008