Diagnostic accuracy of transesophageal echocardiography during cardiopulmonary resuscitation.
نویسندگان
چکیده
OBJECTIVES We sought to establish the diagnostic accuracy of transesophageal echocardiography (TEE) during cardiopulmonary resuscitation. BACKGROUND Because of its bedside diagnostic capabilities, excellent cardiac images and lack of interference with resuscitation efforts, TEE is ideally suited to determine the cause of a circulatory arrest that is not due to severe arrhythmia. However, the diagnostic accuracy of TEE during resuscitation is unknown. METHODS TEE was performed in patients with prolonged circulatory arrest. The TEE diagnoses were compared with diagnoses from autopsy, surgery and clinical follow-up. RESULTS Of the 48 study patients (29 male, 19 female, mean age +/- SD 61 +/- 20 years), 28 had an in-hospital cardiac arrest and 20 an out-of-hospital onset of arrest. Forty-four patients eventually died; four survived to discharge. The diagnoses made with TEE were cardiac tamponade (n = 6), myocardial infarction (n = 21), pulmonary embolism (n = 6), ruptured aorta (n = 1), aortic dissection (n = 4), papillary muscle rupture (n = 1), other diagnosis (n = 2) and absence of structural cardiac abnormalities (n = 7). A definite diagnosis from a reference standard was available in 31 patients. The TEE diagnosis was confirmed in 27 of the 31-by postmortem examination (n = 19), operation (n = 2), angiography (n = 2) or clinical course (n = 4). In the other four patients the TEE diagnosis proved incorrect by postmortem examination. The sensitivity, specificity and positive predictive value of TEE were 93%, 50% and 87%, respectively. In 15 patients (31%), major therapeutic decisions were based on TEE findings. CONCLUSIONS TEE can reliably establish the cause of a circulatory arrest during cardiopulmonary resuscitation.
منابع مشابه
Physiology of blood flow during cardiopulmonary resuscitation. A transesophageal echocardiographic study.
BACKGROUND There are two competing theories of the mechanism of blood flow during cardiopulmonary resuscitation. The "cardiac pump" theory postulates that blood flows because the heart is squeezed between the sternum and the spine. The "thoracic pump" theory postulates that blood flows from the thorax because intrathoracic pressure exceeds extrathoracic vascular pressure and that flow is restri...
متن کاملTransesophageal echocardiography during cardiopulmonary arrest in the emergency department.
Management of patients in cardiopulmonary arrest is challenging and can be resource consuming. Outcomes continue to be poor and physicians may feel a sense of futility when running a resuscitation. Bedside ultrasound has been utilized to guide resuscitations, diagnose correctable cardiac pathology leading to an arrest and has proved to have a prognostic value when utilized in the initial stages...
متن کاملCardiac tamponade during transesophageal echocardiography in the patient of circumferential aortic dissection.
A 43-year-old woman, whose physical findings were consistent with Marfan's syndrome, presented with acute chest pain. Transthoracic two-dimensional echocardiography demonstrated dilated ascending aorta with a circular shape intimal flap at the root level. Subsequently, the patient required transesophageal echocardiography (TEE), but during esophageal intubation, the patient developed acute peri...
متن کاملAortic luminal thrombus and intramural hematoma after cardiopulmonary resuscitation
We describe the case of a patient with an intramural hematoma and floating thrombus after cardiopulmonary resuscitation. The 92-year old man had a cardiac arrest due to ventricular fibrillation and witnesses immediately initiated manual cardiopulmonary resuscitation. Transesophageal echocardiography was performed immediately on hospital admission because the patient was in cardiogenic shock. In...
متن کاملTricuspid annular plane systolic excursion (TAPSE) predicts poor outcome in patients undergoing acute pulmonary embolectomy
INTRODUCTION Right ventricular failure remains a major cause of mortality during acute pulmonary embolism. Right ventricular function can be assessed with transesophageal echocardiography. However, due to the complex right ventricular anatomy, only a few echocardiographic parameters are reliable and easily obtainable intraoperatively. Tricuspid annular plane systolic excursion is a validated pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 30 3 شماره
صفحات -
تاریخ انتشار 1997