Effects of diagnostic guidewire catheter presence on translesional hemodynamic measurements across significant coronary artery stenoses.
نویسندگان
چکیده
This study gains insight on the nature of flow blockage effects of small guidewire catheter sensors in measuring mean trans-stenotic pressure gradients Deltap across significant coronary artery stenoses. Detailed pulsatile hemodynamic computations were made in conjunction with previously reported clinical data in a group of patients with clinically significant coronary lesions before angioplasty. Results of this study ascertain changes in hemodynamic conditions due to the insertion of a guidewire catheter (di=0.46 mm) across the lesions used to directly determine the mean pressure gradient (Deltap) and fall in distal mean coronary pressure (pr). For the 32 patient group of Wilson et al. [1988] (minimal lesion diameter dm=0.95 mm; 90% mean area stenosis; proximal measured coronary flow reserve (CFR) of 2.3 in the abnormal range) the diameter ratio of guidewire catheter to minimal lesion was 0.48, causing a tighter "artifactual" mean area stenosis of 92.1%. The results of the computations indicated a significant shift in the Deltap-Q relation due to guidewire induced increases in flow resistances (R=Deltap/Q) of 110% for hyperemic flow, a 35% blockage in hyperemic flow (Qh) and a phase shift of the coronary flow waveform to systolic predominance. These alterations in flow resulted in a fall in distal mean coronary pressure (at lower mean flow rates) below the patho-physiological range of prh approximately 55 mmHg, which is known to cause ischemia in the subendocardium (Brown et al. [1984]) and coincides with symptomatic angina. Transient wall shear stress levels in the narrow throat region (with flow blockage) were of the order of levels during hyperemic conditions for patho-physiological flow. In the separated flow region along the distal vessel wall, vortical flow cells formed periodically during the systolic phase when instantaneous Reynolds numbers Ree(t) exceeded about 110. For patho-physiological flow without the presence of the guidewire these vortical flow cells were much stronger than in the more viscous flow regime with the guidewire present. The non-dimensional pressure data given in tabular form may be useful in interpretation of guidewire measurements done clinically for lesions of similar geometry and severity.
منابع مشابه
Guidewire flow obstruction effect on pressure drop-flow relationship in moderate coronary artery stenosis.
To evaluate the local hemodynamic effects of coronary artery balloon angioplasty, computational fluid dynamics was applied to representative stenoses geometry post-angioplasty (minimal lesion diameter d(m) = 1.8mm which produced 64% mean area stenoses) based on a group of patients and measured values of coronary flow reserve (CFR) returning to a normal range (3.6+/-0.3). The computations were a...
متن کاملHemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study
BACKGROUND The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true s...
متن کاملEffect of guidewire on contribution of loss due to momentum change and viscous loss to the translesional pressure drop across coronary artery stenosis: An analytical approach
BACKGROUND Guidewire (GW) size and stenosis dimensions are the two major factors affecting the translesional pressure drop. Studying the combined effect of these parameters on the mean pressure drop (Δp) across the stenosis is of high practical importance. METHODS In this study, time averaged mass and momentum conservation equations are solved analytically to obtain pressure drop-flow, Δp-Q, ...
متن کاملIn Vivo Validation of Patient‐Specific Pressure Gradient Calculations for Iliac Artery Stenosis Severity Assessment
BACKGROUND Currently, the decision to treat iliac artery stenoses is mainly based on visual inspection of digital subtraction angiographies. Intra-arterial pressure measurements can provide clinicians with accurate hemodynamic information. However, pressure measurements are rarely performed because of their invasiveness and the time required. Therefore, the aim of the study was to test the feas...
متن کاملCharacterizing momentum change and viscous loss of a hemodynamic endpoint in assessment of coronary lesions.
Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biorheology
دوره 40 6 شماره
صفحات -
تاریخ انتشار 2003