Carotid siphon geometry and variants of the circle of Willis in the origin of carotid aneurysms.
نویسندگان
چکیده
This study evaluated anatomical variants in the carotid siphon and of the circle of Willis in patients with aneurysms. We performed a retrospective analysis of cerebral angiographies. The Control Group was composed of patients without aneurysms. Posterior communicating artery (PcomA) aneurysms were more common in women (p<0.05), and the anterior communicating artery (AcomA) aneurysms in men (p<0.1). The incidence of fetal-type PcomA was higher in cases with co-occurring PcomA aneurysm (24 versus 8%, p<0.05). Patients with AcomA aneurysm had higher incidence of A1 hypoplasia (p<0.0001, OR=32.13, 95%CI 12.95-79.71) and lower frequency of fetal-type PcomA compared to their control counterparts (p=0.0125). The angle of carotid siphon was narrower in patients with PcomA aneurysm (27.3±19.1 versus 34.8±22.6, p=0.028). In conclusion, a narrower carotid siphon or the presence of fetal-type PcomA or A1 hypoplasia may cause hemodynamic stress, thereby promoting the formation of aneurysms in susceptible individuals.
منابع مشابه
بررسی واریاسیونهای آناتومیک حلقه عروقی مغز(حلقه ویلیس) از طریق آنژیوگرافی مغزی
ABSTRACT Anatomical variations have great importance among various medical disciplins. The significance of these variations differ from some points of view including system, site and degree of variation. Vascular system is a common site of variations. The importance of this system in supplying the organs, specially the brain has made it to be in focus for its variations. The main sourc...
متن کاملAnatomical Variations of Circle of Willis in 57 Human Brains
Purpose: The circle of willis is responsible for blood supply of brain, which may suffer from anatomical variations. These disturbances can lead to aneurysm or even arterial rupture. The purpose of this study was to evaluate the anatomical structure of the cerebral arteries forming the circle of willis in adult cadavers. Also, cerebral versus non- cerebral versus non-cerebral arterial walls wer...
متن کاملModeling the Circle of Willis Using Electrical Analogy Method under both Normal and Pathological Circumstances
Background and objective: The circle of Willis (COW) supports adequate blood supply to the brain. The cardiovascular system, in the current study, is modeled using an equivalent electronic system focusing on the COW.Method: In our previous study we used 42 compartments to model whole car- diovascular system. In the current study, nevertheless, we extended our model by using 63 compartments to m...
متن کاملVARIATIONS IN THE CIRCULUS ARTERIOSUS OF WILLIS: AUTOPSY FINDINDS IN 101 HUMAN CADAV ERS
In order to evaluate the microvascular anatomy and the interconnections, 101 fixed brains from human cadavers with a mean age of 41.3 years were subjected to objective scrutiny. Symmetry was visualized with an unaided eye and measurements made under microscopic magnification technique using a micrometer. Classic symmetry was observed in only 19 of the specimens, whereas the rest of the 82...
متن کاملCerebral aneurysms and variations in the circle of Willis.
In order to obtain information about the relationship between variations in the circle of Willis and aneurysms, 44 complete circles of Willis with aneurysm were studied macroscopically. The incidence of variations was significantly higher in the aneurysm series than in the control circles without aneurysm. There was a definite correlation between asymmetric proximal segments of the anterior cer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos de neuro-psiquiatria
دوره 70 12 شماره
صفحات -
تاریخ انتشار 2012