Real-time aortic pulse wave velocity measurement during exercise stress testing
نویسندگان
چکیده
BACKGROUND Pulse wave velocity (PWV), a measure of arterial stiffness, has been demonstrated to be an independent predictor of adverse cardiovascular outcomes. This can be derived non-invasively using cardiovascular magnetic resonance (CMR). Changes in PWV during exercise may reveal further information on vascular pathology. However, most known CMR methods for quantifying PWV are currently unsuitable for exercise stress testing. METHODS A velocity-sensitive real-time acquisition and evaluation (RACE) pulse sequence was adapted to provide interleaved acquisition of two locations in the descending aorta (at the level of the pulmonary artery bifurcation and above the renal arteries) at 7.8 ms temporal resolution. An automated method was used to calculate the foot-to-foot transit time of the velocity pulse wave. The RACE method was validated against a standard gated phase contrast (STD) method in flexible tube phantoms using a pulsatile flow pump. The method was applied in 50 healthy volunteers (28 males) aged 22-75 years using a MR-compatible cycle ergometer to achieve moderate work rate (38 ± 22 W, with a 31 ± 12 bpm increase in heart rate) in the supine position. Central pulse pressures were estimated using a MR-compatible brachial device. Scan-rescan reproducibility was evaluated in nine volunteers. RESULTS Phantom PWV was 22 m/s (STD) vs. 26 ± 5 m/s (RACE) for a butyl rubber tube, and 5.5 vs. 6.1 ± 0.3 m/s for a latex rubber tube. In healthy volunteers PWV increased with age at both rest (R(2) = 0.31 p < 0.001) and exercise (R(2) = 0.40, p < 0.001). PWV was significantly increased at exercise relative to rest (0.71 ± 2.2 m/s, p = 0.04). Scan-rescan reproducibility at rest was -0.21 ± 0.68 m/s (n = 9). CONCLUSIONS This study demonstrates the validity of CMR in the evaluation of PWV during exercise in healthy subjects. The results support the feasibility of using this method in evaluating of patients with systemic aortic disease.
منابع مشابه
Real time phase encoded MR for assessment of acute variability of central pulse wave velocity
Background The variability of pulse wave velocity (PWV) with changing arterial wall stress may reflect the degree of aortic stiffness independent of arterial pressure. We implemented a real-time MR flow technique so as to be able to assess acute changes in PWV due to affected arterial blood and/or intra thoracic pressure. The aim of this study was to assess the accuracy of rapid PWV assessment ...
متن کاملThe effect of exercise on large artery haemodynamics in healthy young men.
BACKGROUND Brachial blood pressure predicts cardiovascular outcome at rest and during exercise. However, because of pulse pressure amplification, there is a marked difference between brachial pressure and central (aortic) pressure. Although central pressure is likely to have greater clinical importance, very little data exist regarding the central haemodynamic response to exercise. The aim of t...
متن کاملAcute effects of ultrafiltration on aortic mechanical properties determined by measurement of pulse wave velocity and pulse propagation time in hemodialysis patients
OBJECTIVE The effects of acute hemodialysis session on pulse wave velocity are conflicting. The aim of the current study was to assess the acute effects of ultrafiltration on the aortic mechanical properties using carotid-femoral (aortic) pulse wave velocity and pulse propagation time. METHODS A total of 26 (12 women, 14 men) consecutive patients on maintenance hemodialysis (mean dialysis dur...
متن کاملNoninvasive stress testing. Methodology for elimination of the phonocardiogram.
Measurement by systolic time intervals (STI) of cardiac responses requires extremely careful recording during actual stress test performance. Previous work indicated no significant changes in the pulse transmission time (PTT) during exercise and other challenges. Since external STI depend on the carotid pulse offset by the PTT as an aortic curve equivalent, stable PTT implies that timing of the...
متن کاملReal time MRI pulse wave velocity for exercise stress testing
Methods LV function was assessed by reduced-slice guide-point modelling from 6 SA slices and 2 LA slices acquired using a tGRAPPA accelerated SSFP sequence, as previously validated [1]. Two slices were acquired per breath-hold with a breath-hold duration of 5-8 sec. PWV was acquired in real time at 7.8 msec temporal resolution between two slices located at the pulmonary bifurcation and just abo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2015