3D Surface Imaging of the Human Female Torso in Upright to Supine Positions
نویسندگان
چکیده
Three-dimensional (3D) surface imaging of breasts is usually done with the patient in an upright position, which does not permit comparison of changes in breast morphology with changes in position of the torso. In theory, these limitations may be eliminated if the 3D camera system could remain fixed relative to the woman's torso as she is tilted from 0 to 90°. We mounted a 3dMDtorso imaging system onto a bariatric tilt table to image breasts at different tilt angles. The images were validated using a rigid plastic mannequin and the metrics compared to breast metrics obtained from five subjects with diverse morphology. The differences between distances between the same fiducial marks differed between the supine and upright positions by less than 1% for the mannequin, whereas the differences for distances between the same fiducial marks on the breasts of the five subjects differed significantly and could be correlated with body mass index and brassiere cup size for each position change. We show that a tilt table-3D imaging system can be used to determine quantitative changes in the morphology of ptotic breasts when the subject is tilted to various angles.
منابع مشابه
Sagittal plane moment arms of the female lumbar region rectus abdominis in an upright neutral torso posture.
BACKGROUND Prior imaging studies of torso muscle moment arms for use as inputs into biomechanical models have been derived from subjects lying supine. Recent research suggests moment arms of the rectus abdominis are larger when standing versus lying supine. METHODS Axial MRI images, through and parallel to the intervertebral discs were obtained from five females in a standing upright neutral ...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملEstimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study
Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...
متن کاملLeft ventricular performance in normal subjects: a comparison of the responses to exercise in the upright and supine positions.
Left ventricular (LV) performance at rest and during multilevel exercise in the supine and upright positions was studied in seven normal subjects with equilibrium radionuclide ventriculography. The mean left ventricular end-diastolic volume (LVEDV) during supine rest was 107 4 10 ml (± SEM) and 85 ± 6 ml (p < 0.02) in the upright position; the mean resting left ventricular end-systolic volumes ...
متن کاملUpright and Supine Positions
Left ventricular (LV) performance at rest and during multilevel exercise in the supine and upright positions was studied in seven normal subjects with equilibrium radionuclide ventriculography. The mean left ventricular end-diastolic volume (LVEDV) during supine rest was 107 4 10 ml (± SEM) and 85 ± 6 ml (p < 0.02) in the upright position; the mean resting left ventricular end-systolic volumes ...
متن کامل