Identification, Model Updating, and Validation of a Steel Twin Deck Curved Cable-Stayed Footbridge

نویسندگان

  • Oreste S. Bursi
  • Anil Kumar
  • Giuseppe Abbiati
  • Rosario Ceravolo
چکیده

To perform a realistic reliability analysis of a complex cable-stayed steel footbridge subject to natural hazard and corrosion, this article addresses a rational process of modeling and simulation based on identification, model updating, and validation. In particular, the object of this study is the Ponte del Mare footbridge located in Pescara, Italy; this bridge was selected as being a complex twin deck curved footbridge because it is prone to corrosion by the aggressive marine environment. With the modeling and simulation objectives in mind, a preliminary finite element (FE) model was realized using the ANSYS software. However, uncertainties in FE modeling and changes during its construction suggested the use of experimental system identification. As a result, the sensor location was supported by a preliminary FE model of the footbridge, although to discriminate close modes of the footbridge and locate identification sensor layouts, Auto Modal Assurance Criterion (AutoMAC) values and stabilization diagram techniques were adopted. Modal characteristics of the footbridge were extracted from signals produced by ambient vibration via the stochastic subspace identification (SSI) algorithm, although similar quantities were identified with free-decay signals produced by impulse excitation using the ERA algorithm. All these procedures were implemented in the Structural Dynamic Identification Toolbox (SDIT) code developed in a MATLAB environment. The discrepancies between analytical and experimental frequencies led to a first update of the FE model based on Powell’s dog-leg method that relied on ∗To whom correspondence should be addressed. E-mail: Oreste. [email protected]. a trust-region approach. As a result, the identified FE model was capable of reproducing the response of the footbridge subject to realistic gravity and wind load conditions. Finally, the FE was further updated in the modal domain, by changing both the stationary aerodynamic coefficients and the flutter derivatives of deck sections to take into account the effects of the curved deck layout.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Pedestrian Walking Loads on a Cable Stayed Footbridge Using Modal Testing and Fe Model Updating

This paper describes the finite element modelling, dynamic testing and finite element model updating of a newly constructed, 35m span, cable-stayed footbridge. A numerical simulation, using an updated FE model, was conducted to evaluate the accelerations that would be induced by a walking pedestrian. The results from the simulation were compared to corresponding experimental measurements, and w...

متن کامل

Probabilistic Identification of Simulated Damage on the Dowling Hall Footbridge through Bayesian FE Model Updating

This paper presents a probabilistic damage identification study on a full-scale structure, the Dowling Hall Footbridge, through a Bayesian finite element (FE) model updating. The footbridge is located at Tufts University and is equipped with a continuous monitoring system that measures its ambient acceleration response. A set of data is recorded once every hour or when triggered by large vibrat...

متن کامل

Construction of Nagisa Bridge Hybrid System of Cable-stayed Pc Bridge and Steel Suspension Bridge

Nagisa Bridge, a single span footbridge, was recently completed in Aomori prefecture, Japan. The structure of this bridge is a hybrid structure of cable-stayed prestressed concrete bridge and steel suspension bridge. It is the first application as this structure type of bridge in the world. Concrete girders near pylons are supported by stay cables. Steel girders are supported by suspension cabl...

متن کامل

Study on the System Reliability of Steel-Concrete Composite Beam Cable-stayed Bridge

Abstract: Steel-concrete composite beam cable-stayed bridge is a complicated system consisting of a composite beam, tower, and stayed cables. And the composite beam is composed of a steel beam, bridge deck and connectors, which has a different mechanical behavior from the general beam structure. In a word, the steel-concrete composite beam cable-stayed bridge is characterized by specific mechan...

متن کامل

Dynamic characteristics of the new curved cable-stayed bridge in Porto Marghera (Venice, Italy) from ambient vibration measurements

The paper summarizes the results of recent ambient vibration tests and operational modal analyses carried out on the new curved cable-stayed bridge erected in the Commercial Harbour of Porto Marghera (Venice, Italy). The ambient vibration tests were carried out as a part of the reception tests of the bridge before its opening and included the recordings of the system response in selected points...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Comp.-Aided Civil and Infrastruct. Engineering

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2014