Quality assurance devices for dynamic conformal radiotherapy

نویسنده

  • Victy Y.W. Wong
چکیده

Two quality control devices, light-field device and radiation-field device, have been specially designed to facilitate the clinical implementation of conformal dynamic arc treatment (CDAT) and intensity modulated radiation therapy (IMRT). With the devices, the light field as well as the radiation field, projected from the individual beam at any treatment position (i.e. arbitrary gantry angle) can be evaluated. For application, the device was attached at the front end of the couch and was placed at the isocentre of the linear accelerator treatment system (LINAC). The devices are designed to be rotated parallel to the gantry head so that the light field and the radiation field projected from a direct beam can be assessed. The aim of the study is, with the aid of the devices, to evaluate the geometric precision of the beam placement and the dosimetric accuracy performed in CDAT and IMRT. The devices are placed separately from the LINAC during application and provide an independent check on the quality performance of the LINAC in three dimensions. The condition of gantry sag and any mechanical displacement resulting in field shift can be observed and traced during gantry rotation. Mistakes that occurred during the isocentre calibration can lead to significant displacement in the field projection, which would not be revealed with the conventional quality control setting (i.e. gantry 0(o)), was demonstrated with the aid of the devices here. The influence of gravitational acceleration in MLC leaf positioning error, which would consequently lead to inaccurate dose delivery, was investigated. The results of our study show that the existence of gravitational influence is statistically significant, although the magnitude of the dose inaccuracy has been found to be small.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

dimensional film dosimetry with GAFCHROMIC films for quality assurance and dosimetric verification of 3D conformal radiotherapy in the presence of heterogeneities

Introduction: The presence of heterogeneities such as air-filled cavities in the head and neck treatment fields region, may result in potential dosimetric disagreement because the losses of charged particle equilibrium. Most of treatments planning systems are not able to predict dose distribution of inhomogeneities region accurately. Therefore, dose calculation algorithms need to...

متن کامل

Quality assurance in conformal radiotherapy: DYNARAD consensus report on practice guidelines.

BACKGROUND AND PURPOSE Conformal radiotherapy has only recently been widely implemented. Although not all aspects have yet been adequately proven, it is generally recognized that maintaining a high degree of precision throughout the process is critical to the treatment outcome while the focus for quality assurance and quality improvement will need to concentrate more on human factors, procedure...

متن کامل

Design of an Anthropomorphic Intensity Modulated Radiation Therapy Quality Assurance Phantom

The dynamic nature of IMRT delivery poses unique problems relating to the accurate and reproducible quality assurance of dose delivery. The usefulness of point detectors is limited to static fields and regions within low dose-gradients for treatment verification. However, dose distributions generated in intensity modulated radiation therapy (IMRT) often have complex shapes with high dose gradie...

متن کامل

Radiotherapy for Prostate Cancer: is it 'what you do' or 'the way that you do it'? A UK Perspective on Technique and Quality Assurance.

AIMS The treatment of prostate cancer has evolved markedly over the last 40 years, including radiotherapy, notably with escalated dose and targeting. However, the optimal treatment for localised disease has not been established in comparative randomised trials. The aim of this article is to describe the history of prostate radiotherapy trials, including their quality assurance processes, and to...

متن کامل

Dosimetric Study of Tissue Heterogeneity Correction for Breast Conformal Radiotherapy

Introduction: Heterogeneity correction is an important parameter in dose calculation for cancer patients where it may be cause inaccuracy in dose calculation as a result of different densities of patients. This study studied the impact of dose calculation of breast cancer patients with and without heterogeneity correction. Material and Methods: Twenty breast cancer patients were treated with Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2004