Performance test of digital breast tomosynthesis using a dedicated phantom
نویسندگان
چکیده
منابع مشابه
Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملPower Spectrum Analysis of an Anthropomorphic Breast Phantom Compared to Patient Data in 2D Digital Mammography and Breast Tomosynthesis
Digital breast tomosynthesis (DBT) images of a novel anthropomorphic breast phantom (UPenn phantom) acquired on two breast tomosynthesis systems were analyzed in terms of their power spectra (PS). The β and κ power law coefficients were estimated from 2D planar, tomosynthesis projection images and reconstructed planes. These data were compared to the PS characteristics as retrieved from a group...
متن کاملAn Object-Oriented Simulator for 3D Digital Breast Tomosynthesis Imaging System
Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to...
متن کاملDigital breast tomosynthesis (DBT) versus full field digital mammography (FFDM): comparison of a system performance using a contrast detail phantom
To evaluate performance (image signal to noise ratio) of a digital mammographic system working in 2D planar versus tomosynthesis modality, a contrast detail phantom was developed embedding 1 cm plexyglas, including 49 holes of different diameter and depth, between two layers containing a breast simulating material. The acquisition protocol included 15 low dose projections (reconstructed 1mm-thi...
متن کاملDosimetry in x-ray-based breast imaging
The estimation of the mean glandular dose to the breast (MGD) for x-ray based imaging modalities forms an essential part of quality control and is needed for risk estimation and for system design and optimisation. This review considers the development of methods for estimating the MGD for mammography, digital breast tomosynthesis (DBT) and dedicated breast CT (DBCT). Almost all of the methodolo...
متن کامل