IOL Tilt and Decentration Estimation from 3 Dimensional Reconstruction of OCT Image
نویسندگان
چکیده
PURPOSE To evaluate intraocular lens (IOL) tilt and decentration by anterior segment optical coherence tomography (AS-OCT) using 3-dimensional (3D) reconstruction method. DESIGN Prospective observational case series. PARTICIPANTS Thirty-nine patients (39 eyes) were included. METHODS The IOL positions of all eyes were examined by AS-OCT. Images were obtained in 4 axes (0-180 degrees, 45-225 degrees, 90-270 degrees, and 135-315 degrees) using the quadrant-scan model. The cross-sectional images were analyzed with MATLAB software. MAIN OUTCOME MEASURES The angle (θ) between the reference pupillary plane and the IOL plane, the distances between the center points of the pupil circle and the IOL on the x-axis (dx) and y-axis (dy) and the spatial distance (ds) were calculated after 3D-reconstruction. RESULTS The mean angle (θ) between the pupillary plane and the IOL plane was 2.94±0.99 degrees. The mean IOL decentration of dx and dy was 0.32±0.26 mm and 0.40±0.27 mm, respectively. The ds of the IOL decentration was 0.56±0.31 mm. There was no significant correlation between the ocular residual astigmatism (ORA) and the tilted angle or the decentration distance. There was a significant correlation between the ORA and total astigmatism (r = 0.742, P<0.001). There was no significant correlation between the postoperative best corrected visual acuity (BCVA) and the ORA (r = 0.156; P = 0.344), total astigmatism (r = 0.012; P = 0.942), tilted angle (θ; r = 0.172; P = 0.295) or decentration distance (dx: r = 0.191, P = 0.244; dy: r = 0.253, P = 0.121; ds: r = 0.298, P = 0.065). CONCLUSIONS AS-OCT can be used as an alternative for the analysis of IOL tilt and decentration using 3D-reconstruction.
منابع مشابه
Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting
The tilt and decentration of intraocular lens (IOL) result in defocussing, astigmatism, and wavefront aberration after operation. The objective is to give a method to estimate the tilt and decentration of IOL more accurately. Based on AS-OCT images of twelve eyes from eight cases with subluxation lens after operation, we fitted spherical equation to the data obtained from the images of the ante...
متن کاملIntraocular lens alignment from an en face optical coherence tomography image Purkinje-like method
Mengchan Sun Alberto de Castro Sergio Ortiz Pablo Perez-Merino Judith Birkenfeld Susana Marcos Instituto de Óptica “Daza de Valdés” Consejo Superior de Investigaciones Científicas Serrano 121 28006 Madrid, Spain E-mail: [email protected] Abstract. Measurement of intraocular lens (IOL) alignment implanted in patients in cataract surgery is important to understand their optical performance....
متن کاملIntraocular lens alignment from purkinje and Scheimpflug imaging.
The improved designs of intraocular lenses (IOLs) implanted during cataract surgery demand understanding of the possible effects of lens misalignment on optical performance. In this review, we describe the implementation, set-up and validation of two methods to measure in vivo tilt and decentration of IOLs, one based on Purkinje imaging and the other on Scheimpflug imaging. The Purkinje system ...
متن کاملAssessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography
PURPOSE To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). METHODS A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at...
متن کاملTilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.
PURPOSE To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. SETTING Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. METHODS Measurements of IOL tilt and decentration were obtained using a commercial Schei...
متن کامل