Determination of neutron temperature in irradiation channels of reactor

نویسنده

  • Tran Van Hung
چکیده

The neutron temperature is a characteristic parameter in irradiation channels of reactor. For nuclides which have resonances in the thermal neutron energy range, their Westcott g-factors are different from unity. The values of g-factors and cross-sections of (n, γ) reaction of these nuclides are temperature dependence. The standard energy for tabulation of thermal neutron cross-section (σ0) is that of room temperature (293.59 K or 20.43 °C), corresponding to a neutron energy 0.0253 eV or to a neutron velocity of 2200 m/s. However, in the irradiation channels of reactor, the temperature is not exact at 20.43 °C. Thus, the temperature at the irradiation position must be known to convert σ0 to σ(T). A method for determination of the neutron temperature in irradiation channels of Dalat reactor is presented by fitting the thermal neutron spectrum obtained from the calculation using MCNP code.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of neutron and gamma dose in the MNSR research reactor

In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...

متن کامل

Modified method of α determination in the 1/E1+α epithermal neutron spectrum of reactor

A modified method has been developed for the α determination in the 1/E1+α epithermal neutron spectrum of reactor. It is based on the Cd-covered and without Cd-covered irradiations of two monitors. This method was applied to determine the α value in the channels of Dalat reactor and the results were compared with those obtained by the other methods. It appeared that the results of the modified ...

متن کامل

Radiation Safety Assessment of the New Neutron Radiography System at Tehran Research Reactor

Recently, a new Neutron Radiography (NR) beam line has been designed, constricted, installed and tested based on the use of E-beam tube of Tehran Research Reactor (TRR). Initial tests have been shown that the system can be used for different samples and purposes such as nuclear plates and rods fuels.  For this end the system need a suitable irradiation room which should be installed at the NR b...

متن کامل

Determination of Neutron Fluxes and Spectrum Shaping Factors in Irradiation Sites of Ghana’S Miniature Neutron Source Reactor (mnsr) by Activation Method After Compensation of Loss of Excess Reactivty

Accurate neutron flux values in irradiation channels of research reactors are very essential to their usage. The total neutron flux of the Ghana Research Reactor-1 (GHARR-1) was measured after a beryllium reflector was added to its shim to compensate for excess reactivity loss. The thermal, epithermal and fast neutron fluxes were determined by the method of foil activation. The experimental sam...

متن کامل

Modeling the measurement of VVER-1000 reactor power by neutron and gamma radiation with MCNP code

The present study deals with a new method for measuring the power of a reactor. This method uses gamma and neutron radiation resulted from the entire reactor structure, without changing its structure (online). In terms of functionality, this method can measure the reactor power in real-time and report it instantly. In order to obtain the relationship between reactor power and gamma and neutron ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 287  شماره 

صفحات  -

تاریخ انتشار 2011