Mechanism of Corrosion of Steel Strands in Post Tensioned Grouted Assemblies
نویسندگان
چکیده
In this preliminary study, the complexity of the corrosion phenomenon of post-tensioning strands in grouted anchorage assemblies was examined and both physicochemical and electrochemical key technical issues were identified. Measurements of oxygen reduction efficiency in high pH electrolytes were conducted to obtain polarization parameters to be used in modeling. The time evolution of electrical resistivity of 5 low-bleed commercial grouts was measured also for model input. A mathematical model for a simple grout-strand system was proposed and dimensionless equations were formulated, to solve the combined polarization and oxygen transport problem. Within the range of validity of the model assumptions, initial computations indicated that oxygen availability was a key factor in determining corrosion severity while grout resistivity was secondary. Predicted corrosion rates were in general agreement with field and laboratory observations. Issues for subsequent model development were identified.
منابع مشابه
08398 - Detection of Corrosion of Post-tensioned Strands in Grouted Assemblies
The feasibility and sensitivity of electrochemical noise (EN), electrochemical impedance spectroscopy (EIS), and linear polarization resistance (LPR) for detection of corrosion in post-tensioning (PT) components was investigated. The use of the electrical resistance (ER) technique, as well EIS and LPR, to detect air space corrosion at the grout voids was also explored. The results showed that h...
متن کاملPost-Tensioned Steel Connections Self-Centering Behavior Using the Finite Element Method
Due to lack of the proper and well behavior of steel moment-resisting connections subjected to the great and major earthquakes, excessive researches have been conducted to mitigate the damages on the primary elements and connections. Therefore, elimination of residual drift and increasing the plastic rotation capacity for the connectors in the panel zone are required. The main purpose of this s...
متن کاملFailure Of Prestressing Steel Induced By Crevice Corrosion In Prestressed Concrete Structures
The application of prestressed concrete technology in civil structures is relatively recent. Therefore, the existing prestressed concrete members in such structure are still relatively young, and the corrosion and the concrete deterioration problems associated with this type of concrete members have became clearly evident only in the early 1980s. Damage during service, frequently appearing afte...
متن کاملFlexural Strengthening of Deficient Reinforced Concrete Beams with Post-Tensioned Carbon Composites using Finite Element Modelling
The application of external post-tensioned steel bars as an effective way to strengthen an existing bridge has been so far used in many different countries. In recent decades, however, they have been replaced by bars made from Carbon Fiber Reinforced Polymer (CFRP), as a material with high tensile strength and corrosion resistance, to address several concerns with steel bars such as their appli...
متن کاملDamage Detection in Post-tensioned Slab Using 2D Wavelet Transforms
Earthquake force, loading more than structural capacity, cracking, material fatigue and the other unpredicted events were undeniable in the structure life cycle in order that environmental conditions of the structure would be changed and treats health. Damage of structures such as crack, corrosion of the post tension cables from inappropriate grouting of the post tension structures and etc. can...
متن کامل