Autograft contamination during preparation for anterior cruciate ligament reconstruction.

نویسندگان

  • Michael E Hantes
  • Georgios K Basdekis
  • Sokratis E Varitimidis
  • Dimitrios Giotikas
  • Efthimia Petinaki
  • Konstantinos N Malizos
چکیده

BACKGROUND The autograft preparation process for anterior cruciate ligament reconstruction has a potential for graft contamination. The purpose of this study was to evaluate the possibility of contamination of the bone-patellar tendon-bone and hamstring tendon autograft during preparation for anterior cruciate ligament reconstruction. METHODS A primary isolated reconstruction of the anterior cruciate ligament with use of bone-patellar tendon-bone autograft (thirty patients) and hamstring tendon autograft (thirty patients) was performed in a prospective, consecutive series of patients. Three tissue samples were obtained for culture from each graft at different time-intervals during the graft preparation. In addition, the erythrocyte sedimentation rate and the C-reactive protein level were evaluated preoperatively and on the third, seventh, and twentieth postoperative days, and the clinical course of all patients was monitored. RESULTS The time needed for graft preparation was significantly longer for hamstring autografts (nineteen minutes) than for bone-patellar tendon-bone autografts (ten minutes) (p = 0.032). In the hamstring group, cultures of graft tissue from four patients (13%) were positive for bacteria. In the bone-patellar tendon-bone group, cultures of graft tissue from three patients (10%) were positive for bacteria; the difference between groups was not significant (p = 0.923). No patient had development of a postoperative infection. There were no differences between patients with a contaminated graft and those with an uncontaminated graft with regard to postoperative changes in the erythrocyte sedimentation rate or the C-reactive protein level at all time-intervals. CONCLUSIONS A high rate (12%) of autograft contamination can be expected during autograft preparation for anterior cruciate ligament reconstruction. The contamination rate is almost equal for both bone-patellar tendon-bone and hamstring tendon autografts. We could not identify an association between contaminated grafts implanted in the knee and postoperative inflammatory markers such as the erythrocyte sedimentation rate and the C-reactive protein level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hamstring Graft Preparation Techniques for Anterior Cruciate Ligament Reconstruction

Anterior cruciate ligament reconstruction is one of the most commonly performed procedures in orthopaedics, with more than 125,000 performed in the United States per year. There are several reconstruction graft choices that can be used to reconstruct the native anterior cruciate ligament, with autograft hamstring tendons being one of the most commonly used. Preparation of a hamstring autograft ...

متن کامل

Anterior Cruciate Ligament Reconstruction Basics: Bone–Patellar Tendon–Bone Autograft Harvest

Anterior cruciate ligament reconstruction with bone-patellar tendon-bone autograft has long been considered the graft preference for young, active patients with anterior cruciate ligament injuries. The central-third of the native patellar tendon is a reliable graft and is the preferred option for competitive athletes given its excellent track record with high return-to-play rates and low failur...

متن کامل

The clinical Outcome of One-stage High Tibial Osteotomy and Anterior Cruciate Ligament Reconstruction. A Current Concept Systematic and Comprehensive Review

  Background: Patients with an anterior cruciate ligament-deficient varus-angulated knee may need not only an isolated high tibial osteotomy (HTO), but also an additional anterior cruciate ligament reconstruction (ACLR). A number of prospective clinical trials have been published considering the combination of HTO and ACL reconstruction. Our aim was to investigate whether one-stage combined HTO...

متن کامل

Arthroscopic reconstruction of the anterior cruciate ligament. A comparison of patellar tendon autograft and four-strand hamstring tendon autograft.

We compared the outcome of anterior cruciate ligament reconstruction using hamstring tendon autograft with outcome using patellar tendon autograft at 2 years after surgery. Patients had an isolated anterior cruciate ligament injury and, apart from the grafts, the arthroscopic surgical technique was identical. Prospective assessment was performed on 90 patients with isolated anterior cruciate li...

متن کامل

Quadriceps strength and functional capacity after anterior cruciate ligament reconstruction. Patellar tendon autograft versus allograft.

Harvesting the central third of the patellar tendon for autograft anterior cruciate ligament reconstruction is thought to compromise quadriceps strength and functional capacity. We compared objective measurements of quadriceps strength and functional capacity in athletes after patellar tendon autograft or allograft anterior cruciate ligament reconstruction. We looked at 33 active male patients ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 90 4  شماره 

صفحات  -

تاریخ انتشار 2008