PET-based geometrical calibration of a pinhole SPECT add-on for an animal PET scanner.

نویسندگان

  • Xiao Deng
  • Jean-François Beaudoin
  • Jules Cadorette
  • Charles Naaman
  • Roger Lecomte
  • Rutao Yao
چکیده

We developed SPECT imaging capability on an animal PET scanner to provide a cost effective option for animal SPECT imaging. The SPECT add-on sub-system was enabled by mechanically integrating a multiple-pinhole collimator in the PET detector ring. This study introduces a method to calibrate the geometrical parameters of the SPECT add-on using the PET imaging capability of the scanner. The proposed PET imaging-based calibration method consists of two steps: (1) paint the pinhole apertures of the collimator with a positron emitting radioactive solution; and (2) image the collimator inside the scanner in PET mode. The geometrical parameters of the multi-pinhole SPECT add-on can then be derived directly from a set of PET images by simple linear calculation and used in defining the SPECT system. The method was compared to our implementation of a SPECT calibration approach with model-based fitting of SPECT projection data. The procedure for carrying out the PET imaging-based calibration method is simpler and faster than that of our implementation of the SPECT model-based calibration method. Since it does not require model fitting, the uniqueness of the calibration result is warranted. Better quality SPECT images were reconstructed using the PET-derived calibration parameters rather than our implementation of the SPECT model-based calibration parameters. We conclude that the proposed PET imaging-based calibration method provides a highly effective means for enabling SPECT imaging on a PET scanner.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Small animal imaging using a conventional gamma camera exemplified in studies on the striatal dopaminergic system.

BACKGROUND Small animal imaging has recently been the subject of increasing interest and specific imaging devices in particular for positron emission tomography (PET) have been developed. To bypass limitations arising from high acquisition costs and dependence on an in-house cyclotron unit inevitably associated with PET, a conventional gamma camera has been equipped with a pinhole collimator an...

متن کامل

A method for small-animal PET/CT alignment calibration.

Small-animal positron-emission tomography/computed tomography (PET/CT) scanners provide anatomical and molecular imaging, which enables the joint visualization and analysis of both types of data. A proper alignment calibration procedure is essential for small-animal imaging since resolution is much higher than that in human devices. This work presents an alignment phantom and two different cali...

متن کامل

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

Appropriate collimators in a small animal SPECT scanner with CZT detector.

OBJECTIVE Almost all small animal SPECT is performed with pinhole collimators (PH), including single-PH (SPH) and multi-PH (MPH). In the clinical study, not only PH but also parallel-hole collimator (PAH) is often used in planar and SPECT imaging. However, there have been no comparative studies on image quality with various collimators on the small animal imaging. This study compared the basic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 58 7  شماره 

صفحات  -

تاریخ انتشار 2013