A rate nephelometer for measuring specific proteins by immunoprecipitin reactions.

نویسنده

  • J C Sternberg
چکیده

A kinetic nephelometric method and instrument have been developed for the rapid determination of specific serum proteins by means of immunoprecipitin reactions. The maximum rate of change of scattered light intensity in an antigen-antibody reaction can be made to occur within 60 s after initiation of the reaction and provides a measure of the antigen concentration under antibody excess conditions. A mathematical relationship has been found for the conversion of the nonlinear maximum rate data directly into a linear concentration read-out, making possible the use of single-point calibration. Instrument operating parameters and computations are programmed for a particular analysis by means of machine-readable cards. Antigen-excess samples are detected rapidly by injection of calibrator into the reaction mixture after the rate signal has dropped to a pre-selected level. The method correlates well with both radial immunodiffusion and end-point nephelometric methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of proteins with the Behring Nephelometer. A multicentre evaluation.

The selective multi-protein analyser Behring Nephelometer was examined according to the ECCLS guidelines in a multicentre evaluation involving five laboratories. IgG, IgA, IgM, C-reactive protein, C3c, C4, apolipoprotein A-I and B were measured in serum, and albumin and IgG were measured in cerebrospinal fluid. All values obtained were included in the evaluation without correcting for outliers....

متن کامل

Age- and sex-specific pediatric reference intervals: study design and methods illustrated by measurement of serum proteins with the Behring LN Nephelometer.

We analyzed blood from 450 healthy children and adolescents, ages one to 19 y, as well as term and preterm infants, to define age- and sex-specific reference intervals for numerous blood constituents. Reference intervals were derived by using nonparametric methods to determine the 0.025 and 0.975 fractiles. Ten serum proteins were measured with the Behring LN Nephelometer. Girls over 10 years o...

متن کامل

Immunological properties of two fetus-specific globulins of rat in experimentally induced hepatic lesions.

Two fetus-specific globulins, al and a2·fetoglobulins, were detected in rat fetal serum, and the former was detected in amniotic fluid, using respective monospecific rabbit immune sera. Immunochemical distinction of these two proteins was demonstrated. By polyacrylamide gel disc electrophoresis, al-fetoglobulin was further resolved into fast and slow migrating subcomponents having a similar rea...

متن کامل

Initial evaluation of cystatin C measurement by particle-enhanced immunonephelometry on the Behring nephelometer systems (BNA, BN II).

Serum cystatin C has been suggested as a new marker of glomerular filtration rate (GFR). We describe a fully automated and rapid particle-enhanced nephelometric immunoassay (PENIA) for measuring serum cystatin C on the Behring nephelometer systems (BNA, BN II). Each sample is analyzed in 6 min with as many as 75 samples per batch. The assay covers the range 0.23-7.25 mg/L, up to seven times the...

متن کامل

Evaluation of a Monitor Guided Nephelornetric System ByG. Wider Zentrallabor des Wilhelminenspitals der Stadt Wien

The most cpmmon parameters in the specific protein field, namely the immunoglobulins G, A and M were investigated on the recently developed Immuno Video Nephelometer System (IVNS). This System consists of the nephelometer, a microprocessor controlled program and a monitor screen, where instructions, Standard curve and results are displayed. Scattered light of immuno-complexes is measured at equ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 8  شماره 

صفحات  -

تاریخ انتشار 1977