A Double Silicon Drift Type Detector System for EDS with Ultrahigh Efficiency and Throughput for TEM

نویسندگان

  • S. Kawai
  • I. Onishi
  • T. Ishikawa
  • K. Yagi
  • T. Iwama
  • K. Miyatake
  • Y. Iwasawa
  • M. Matsushita
  • T. Kaneyama
  • Y. Kondo
چکیده

For elemental analysis with energy dispersive X-ray spectroscopy (EDS) in transmission electron microscopy (TEM), the demand for the improved efficiency of X-ray detection, a higher counting rate, is very strong, because the improvement not only results in high throughput, but also extends the method to the specimens fairly susceptible to electron beam damage. We have already developed and introduced into the market an advanced commercial EDS system with a large area silicon drift type detector (SDD). The sensor area of this SDD is as large as 100 mm 2 . The detection efficiency of X-ray in this system increases by approximately four times with respect to the one with a conventional Si (Li) type detector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

Performing elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy-dispersive X-ray spectrometry (SEM/SDD-EDS).

Electron-excited X-ray microanalysis performed in the scanning electron microscope with energy-dispersive X-ray spectrometry (EDS) is a core technique for characterization of the microstructure of materials. The recent advances in EDS performance with the silicon drift detector (SDD) enable accuracy and precision equivalent to that of the high spectral resolution wavelength-dispersive spectrome...

متن کامل

Probe current determination in analytical TEM/STEM and its application to the characterization of large area EDS detectors.

A simple procedure, which enables accurate measurement of transmission electron microscopy (TEM)/STEM probe currents using an energy loss spectrometer drift tube is described. The currents obtained are compared with those measured on the fluorescent screen to enable the losses due to secondary and backscattered electrons to be determined. The current values obtained from the drift tube allow th...

متن کامل

Silicon Lithium Detectors for Synchrotron Energy Dispersive X-Ray Fluorescence Spectroscopy

Introduction Detector description and its principle of operation Detector module. Detector Features and its Performance EDXRF of Fe 55 Spectrum Detector comparison with Silicon Drift Detector SDD Concluding remarks References A Silicon Lithium Si(Li) detector is presented. The detector structure and its working principle are explained. The detector is cooled to 77o K by liquid Nitrogen. The det...

متن کامل

Elemental Analysis of Biological and Cryogenic Samples

Introduction Commercial production of large-area silicon drift detectors (SDDs) heralds an exciting new time in biological elemental analysis. Improved low-energy performance and higher collection efficiencies mean EDS is no longer limited by low count rates and poor solid angles. High count rates can be achieved on all types of materials, including soft biological tissues, without altering nor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014