Three Phase-Grating Moiré Neutron Interferometer for Large Interferometer Area Applications.

نویسندگان

  • D Sarenac
  • D A Pushin
  • M G Huber
  • D S Hussey
  • H Miao
  • M Arif
  • D G Cory
  • A D Cronin
  • B Heacock
  • D L Jacobson
  • J M LaManna
  • H Wen
چکیده

We demonstrate a three phase-grating moiré neutron interferometer in a highly intense neutron beam as a robust candidate for large area interferometry applications and for the characterization of materials. This novel far-field moiré technique allows for broad wavelength acceptance and relaxed requirements related to fabrication and alignment, thus circumventing the main obstacles associated with perfect crystal neutron interferometry. We observed interference fringes with an interferometer length of 4 m and examined the effects of an aluminum 6061 alloy sample on the coherence of the system. Experiments to measure the autocorrelation length of samples and the universal gravitational constant are proposed and discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of the thermal expansion coefficients of ferroelectric crystals by a moiré interferometer

A moiré interferometer is used to measure the thermal expansion of two ferroelectric crystals, LiNbO3 and KTiOPO4. The crystal samples are patterned with a chromium reflective grating and used as a diffractive component in a reflective grating interferometer. The thermal expansion of all the three axes of congruent LiNbO3 and of x and y axes of the flux-grown KTiOPO4 were measured from room tem...

متن کامل

A large-area neutron-interferometer optimized for coherent beam deflection Applications

A large perfect crystal interferometer with two interference loops offers novel applications in neutron interferometry. Coherent beam manipulation with special prism and phase shifter arrangements is discussed and prism materials that are able to preserve beam coherence in case of thicker prisms are investigated. A set of four identical prisms has been used to determine the vertical coherence f...

متن کامل

Tilted-grating approach for scanning-mode X-ray phase contrast imaging.

Among the existent X-ray phase-contrast modalities, grating interferometry appears as a very promising technique for commercial applications, since it is compatible with conventional X-ray tubes and is robust from a mechanical point of view. However, since applications such as medical imaging and homeland security demand covering a considerable field of view, the fabrication of large-area grati...

متن کامل

An electron Talbot interferometer

The Talbot effect [1], in which a wave imprinted with transverse periodicity reconstructs itself at regular intervals, is a diffraction phenomenon that occurs in many physical systems. Here we present the first observation of the Talbot effect for electron de Broglie waves behind a nanofabricated transmission grating. This was thought to be difficult because of Coulomb interactions between elec...

متن کامل

-

In this paper a method for digitally recording four quarter-reference-wave-holograms (by CCD) in a Mach-Zehnder interferometer setup, and reconstructing the object wave-front by numerical method is presented. The terms of direct transmission, auto-correlation and conjugate wave in the four wave reconstruction are cancelled out and only one original object wave is left after overlapping. Reconst...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 120 11  شماره 

صفحات  -

تاریخ انتشار 2018