Continuous monitoring of the performance of hip prostheses.

نویسندگان

  • S L Hardoon
  • J D Lewsey
  • P J Gregg
  • B C Reeves
  • J H P van der Meulen
چکیده

New brands of joint prosthesis are released for general implantation with limited evidence of their long-term performance in patients. The CUSUM continuous monitoring method is a statistical testing procedure which could be used to provide prospective evaluation of brands as soon as implantation in patients begins and give early warning of poor performance. We describe the CUSUM and illustrate the potential value of this monitoring tool by applying it retrospectively to the 3M Capital Hip experience. The results show that if the clinical data and methodology had been available, the CUSUM would have given an alert to the underperformance of this prosthesis almost four years before the issue of a Hazard Notice by the Medical Devices Agency. This indicates that the CUSUM can be a valuable tool in monitoring joint prostheses, subject to timely and complete collection of data. Regional or national joint registries provide an opportunity for future centralised, continuous monitoring of all hip and knee prostheses using these techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case study of Performance Improvement of Femur Prosthesis

Nowadays, the placement of artificial prostheses in human skeleton, etc. is common due to different reasons such as fractures or deficiencies. Prostheses are structures that assist the performance of organs by reconstruction of some body parts through different methods to enable the organ to re-obtain its performance completely or partially and, since the use of external prostheses might lead t...

متن کامل

Bilateral Staged Total Hip Replacement and the Natural Progress of an Untreated Case of Developmental Dysplasia (Dislocation) of the Hip: A Clinical Case Report by the Surgeon and the Patient

The natural history of an untreated case of a Developmental Dysplasia (Dislocation) of the Hip (DDH) associated with multiple congenital abnormalities is reported in a 55-years-old man. The patient’s complaints and the varieties of the typical manifestations emerged in other parts of the body throughout the life are reviewed and discussed as comorbidities of a dysplastic condition. Two-stage bi...

متن کامل

Failure of the uncoated titanium ProxiLock femoral hip prosthesis.

UNLABELLED New prostheses should be evaluated for stability and clinical performance. In a prospective randomized clinical trial, we implanted 22 titanium (Ti) and 20 hydroxyapatite-coated (HA) ProxiLock femoral hip prostheses during total hip arthroplasty in 42 patients. The patients were followed for 24 months with clinical, radiographic and radiostereometric analysis. Full weightbearing was ...

متن کامل

Process Performance of a Granular Single Bioreactor with Continuous Feeding and Intermittent Discharge Regime Treating Dairy Wastewater

In this study, granulated sludge synthesized in a sequence batch reactor (SBR) and then granulated sludge was transferred to continuous feeding and intermittent discharge (CFID) bioreactor. Two independent variables (air flow rate and hydraulic retention time (HRT)) were considered to optimize the process. Subsequently, long term performance (150 days) of the bioreactor was assessed by monitori...

متن کامل

ارزیابی عملکرد بیماران پس از آرتروپلاستی هیپ با پروتز Short-stem و Standard-stem : کارآزمایی بالینی تصادفی

Background: Short-stem prosthesis for total hip arthroplasty (THA) have been designed to overcome the weakness of standard-stem prostheses and improve surgical outcomes. The aim of this study was to compare short-stem with standard-stem prosthesis outcomes. Methods: This study was performed as a randomized clinical trial. Subjects were selected among patients referred to Sina University Hospit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 88 6  شماره 

صفحات  -

تاریخ انتشار 2006