Relative risks of different types of contact lenses.
نویسنده
چکیده
potassium concentrations by flame photometry (within batch SD=0 03 mmol/l). The Mann-Whitney U test and Spearman's rank correlation coefficient were used in statistical analysis. The median (range) difference in potassium concentration between serum and plasma in the 43 patients with rheumatoid arthritis was 0 3 (0 1-1 3) mmol/l, which was significantly greater (p<0 001) than that in the 21 controls with arthritis (0 2 (0-0 4) mmol/l) and the 28 normal subjects (0 2 (0-0-4) mmol/l). Serum creatinine and plasma potassium concentrations and the white cell count were similar in the three groups, but the platelet count was significantly (p<0-001) higher in the patients with rheumatoid arthritis (median (range) 366 (165-1260)x 103/1 v 287 (122-444)x 107/1 in the controls with arthritis and 305 (192-440)x 107/1 in the normal subjects). The difference in potassium concentration between serum and plasma in the patients with rheumatoid arthritis correlated with their platelet count (figure) (r=0 64, p<0001). Comment We are not aware of other reports of pseudohyper-kalaemia occurring in conditions such as rheumatoid arthritis. We found that in normal subjects the median serum potassium concentration was 0-2 mmol/l higher than the plasma potassium concentration, which confirms a previous report.4 We found a similar difference in our control group of patients with arthritis who were taking non-steroidal anti-inflammatory drugs, which excludes these as the cause of the pseudohyperkalaemia. In contrast, the difference in concentrations was significant in the patients with rheumatoid arthritis, with values of 1 5 mmol/l being recorded (case 2). The pseudo-hyperkalaemia may have been due to the raised platelet count in view of the correlation between it and the difference between serum and plasma potassium concentrations. Failure to recognise pseudohyperkalaemia in our patients led to errors in management: one patient was given treatment to lower her potassium concentration
منابع مشابه
The effect of polar copolymers in protein absorption on contact lenses on 2-Hydroxyethyl methacrylate(HEMA)
For the purpose of increasing the permeability to oxygen and equilibrium water content in contact lenses, polar copolymers with nonionic monomers such as 2-hydroxyethle methacrylate(HEMA) Is used. By adding the polar monomers to (HEMA), the permeability to oxygen and equilibrium with water content is increased and also the absorption of proteins on lens surface is changed. In this research, the...
متن کاملPower Profiles of Commercial Multifocal Soft Contact Lenses
PURPOSE To evaluate the optical power profiles of commercially available soft multifocal contact lenses and compare their optical designs. METHODS The power profiles of 38 types of multifocal contact lenses-three lenses each-were measured in powers +6D, +3D, +1D, -1D, -3D, and -6D using NIMO TR1504 (Lambda-X, Belgium). All lenses were measured in phosphate buffered saline across 8 mm optic zo...
متن کاملThe study of Lysozyme adsorption onto 2-hydroxyethylmethacrylates and Silicon Hydrogel Contact Lenses
In order to increase the water content and the oxygen permeability of hydrogels used in themanufacture of contact lenses, the polar monomer Silicon Hydrogel Contact Lenses (SHCL), and 2-hydroxyethyl methacrylate (HEMA) were copolymerized with the hydrogels. Due to the presence ofpolar monomers in the conventional contact lenses, the major component of the human tear,lysozyme is extensively adso...
متن کاملThe epidemiology of contact lens related infiltrates.
With estimated numbers of contact lens wearers worldwide exceeding 140 million, even complications with a low incidence will affect a significant number of individuals. Although contact lenses clearly have many advantages for wearers, certain risks have been associated with their use. Differences in risk for different types of contact lenses and wearing patterns have been demonstrated for both ...
متن کاملبررسی کونژنکتیویت با پاپی های غول آسا وابسته به کنتاکت لنز در 700 بیمار
In view of the rapid expansion of contact lens amongst the users, new dimensions have been added to the domain of ophthalmology: Giant papillay conjunctivitis, a disease caused by different kinds of contact lens, appears weeks or months after they are used, although some patients are struck years later. The predominant symptoms are increased awareness of lenses, ocular itching, blurred vision a...
متن کاملمیزان استفاده و آگاهی دانشآموزان دبیرستانهای دخترانهی شهر زنجان از لنزهای طبی _ رنگی در سال تحصیلی 1382
Background & objective: The aim of this study was to investigate the knowledge and use of contact lenses by high school female students in Zanjan in 2003. Materials & Methods: The designed questionnaire was randomly distributed among the high school female students. Then the questionnaire’s questions were standardized based on the study. The main sample size was 700. The samples were selected o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMJ
دوره 297 6647 شماره
صفحات -
تاریخ انتشار 1988