Direct potentiometric determination of sodium ion in blood. III. Influence of (bi)carbonate.

نویسندگان

  • F B Boink
  • P Bijster
  • K L Vink
  • A H Maas
چکیده

We measured the emf of a sodium ion-selective electrode in NaCl-NaHCO3 solutions (160 mmol of Na+, 160-120 mmol of Cl-, and 0-40 mmol HCO3- per liter) with a home-built cell in steady-state after 10 min and with two commercial direct potentiometric analyzers about 20 s after the sample was introduced. Substitution of HCO3- for Cl- resulted in a small decrease in emf. We calculated the effect of chloride ion replacement by bicarbonate ion on the liquid-junction potential and found that this accounted only for one-third of the emf decrease. The exact composition of bicarbonate solutions is closely related to the pH. To control the formation of carbonate, we performed measurements with the home-built cell at two pH values (7.0 and 8.2), controlled by tonometry with carbon dioxide. From the differences in the slope of the emf vs the amount of bicarbonate added at the two pHs we calculated the thermodynamic association constants of the sodium bicarbonate and sodium carbonate complexes (KNaHCO3(0) = 0.53 and KNaCO3- = 24). We conclude that, for the direct potentiometric measurement of sodium ion, only fresh serum should be used, to avoid pH changes. Replacement of sodium chloride by sodium bicarbonate caused different results when emf was measured with commercial analyzers, owing to their short measuring time of about 20 s.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion

A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...

متن کامل

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

Determination of Chromium(III) and Magnesium(II) Ions in Pharmacological and Real Water Samples using Potentiometric Sensors based on Chitosan Schiff base Derivative as Green and Sensitive Ionophore

In the study, novel and sensitive carbon paste electrodes (CPEs) developed for thepotentiometric measurement of Cr(III) and Mg(II) ions in pharmacological and water samples.CPEs as indicator electrodes were prepared from a mixture of four components, includinggraphite powder, paraffin oil, multi-walled carbon nanotubes (MWCNTs), and a greenionophore (Chitosan Schiff base...

متن کامل

Procedure for the simultaneous determination of tartaric and citric acids and total carbonate by potentiometric titrimetry and its application to antacid analysis.

The application of a linear algebraic method to the potentiometric titration of a mixture of tartaric and citric acids and sodium carbonate and sodium hydrogen carbonate (previously treated with strong acid), permits the determination of the concentration of each individual acid and the total equivalent of carbonate in antacids. It is also possible to determine individual concentrations of sodi...

متن کامل

Determination and Modeling of Activity Coefficients of Sodium Chloride in (Glycerol + Water) Mixtures Based on Potentiometric Measurements

In this work, the results concerning to the mean activity coefficient measurements for NaCl in the (glycerol + water) system using the potentiometric method are reported. The potentiometric measurements were performed on the galvanic cells without liquid junction of the type: Ag|AgCl|NaCl (m), glycerol (wt%), H2O (1 - wt)%|Na-ISE, in various mixed solvent systems containing 0, 5, 10,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 1985