Clinical signs caused by the use of electric training collars on dogs in everyday life situations
نویسندگان
چکیده
The use of electric shock collars for training dogs is the subject of considerable controversy. Supporters claim that they are a reliable means of eliminating self-rewarding behaviour and that they can be used over greater distances and with less risk of stress and injury than mechanical devices, such as choke chains. Opponents cite the risk of incorrect or abusive use and temptation to use electric training collars without thought or time given to alternative training methods, regardless of the fact that their use may be associated with pain and fear. The aim of this study was to investigate whether any stress is caused by the use of electric shock collars or not and in this way to contribute to their evaluation with respect to animal welfare. Fourteen laboratory-bred Beagles were used to ensure standardised breeding, raising and training. Heart rate and saliva cortisol were used as stress parameters. The research project lasted for 7 months, during which each dog was trained for 1.5 h per day. To exclude circadian deviations of salivary cortisol values, each individual was allocated a rigid timeslot. Training as well as the experiments themselves were conducted in a secluded storage building to exclude the influence of external stressors. Three experimental groups were used. Group A (Aversion) received the electric shock when the dogs touched the prey—a rabbit dummy fixed to a motion device. Group H (Here) received the electric shock when they did not obey a previously trained recall command during hunting. Animals of group R (Random) received the electric shock arbitrarily, i.e. the shock was administered unpredictably and out of context. The main experiment lasted for 17 days. All animals were allowed to hunt unimpeded for the first 5 days. For the next 5 days the dogs were stopped from hunting by a leash. Every day, the stress parameters were determined. These values were compared with the values that were obtained during the use of the electric training collars. The collars were used over a period of 7 days as described previously. After 4 weeks the dogs were brought back into the research area without receiving an electric pulse. www.elsevier.com/locate/applanim Applied Animal Behaviour Science 105 (2007) 369–380 § This paper is part of the special issue entitled ‘‘Veterinary Behavioural Medicine’’ guest edited by Daniel Mills and Gary Landsberg. * Corresponding author. Tel.: +49 511 953 8494; fax: +49 511 953 8056. E-mail address: [email protected] (E. Schalke). 0168-1591/$ – see front matter # 2006 Elsevier B.V. All rights reserved. doi:10.1016/j.applanim.2006.11.002 Group A did not show a significant rise in salivary cortisol levels, while group R and group H did show a significant rise. When the animals were reintroduced to the research area after 4 weeks, the results remained the same. This led to the conclusion that animals, which were able to clearly associate the electric stimulus with their action, i.e. touching the prey, and consequently were able to predict and control the stressor, did not show considerable or persistent stress indicators. # 2006 Elsevier B.V. All rights reserved.
منابع مشابه
A serological survey on Brucella canis in companion dogs in Ahvaz
Canine brucellosis is a zoonotic infectious disease caused by Brucella canis. This bacterium can be transmitted to humans as well as other dogs. It is a significant cause of reproductive failure, predominantly in kennels. The aim of this study was to determine the seroprevalence of Brucella canis infection in companion dogs referred to the Veterinary Hospital of Shahid Chamran University of Ahv...
متن کاملCorrection: The Welfare Consequences and Efficacy of Training Pet Dogs with Remote Electronic Training Collars in Comparison to Reward Based Training
This study investigated the welfare consequences of training dogs in the field with manually operated electronic devices (e-collars). Following a preliminary study on 9 dogs, 63 pet dogs referred for recall related problems were assigned to one of three Groups: Treatment Group A were trained by industry approved trainers using e-collars; Control Group B trained by the same trainers but without ...
متن کاملPrevalence of Ehrlichia Canis Infection in Uşak and Investigation of Clinical, Hematological and Biochemical Signs in Infected Dogs
Canine ehrlichiosis which becomes widespread worldwide is generated by a pathogen bacteria called Ehrlichia Canis. The prevalence of ehrlichiosis changes according to geographic regions in veterinary practice. The aim of this study was to determine the prevalence of the canine ehrlichiosis in Uşak, Turkey, together with clinical, hematological and biochemical signs. 100 dogs found in 6 differen...
متن کاملThe first report of concurrent detection of canine parvovirus and coronavirus in diarrhoeic dogs of Iran
Two male dogs at the age of 3 and 5 months of Doberman pinscher and German shepherd breeds were referred to the Veterinary Hospital of Ahvaz University with clinical signs of depression, vomiting, haemorrhagic diarrhoea, profound dehydration, fever and anorexia. The affected dogs had not the history of vaccination. Concurrent infection of canine parvovirus and coronavirus was detected in dogs b...
متن کاملThe use of electronic collars for training domestic dogs: estimated prevalence, reasons and risk factors for use, and owner perceived success as compared to other training methods
BACKGROUND The use of electronic training devices for dog training is controversial. The aims of this study were to give an indication of the extent to which dog owners use these devices in England, identify factors associated with their use, and compare owner report of outcomes. A convenience sample of dog owners in England was used to identify numbers using electronic training devices and ide...
متن کامل