Magnetic resonance to assess the aortic valve area in aortic stenosis: how does it compare to current diagnostic standards?

نویسندگان

  • Anna S John
  • Thorsten Dill
  • Roland R Brandt
  • Matthias Rau
  • Wolfgang Ricken
  • Georg Bachmann
  • Christian W Hamm
چکیده

OBJECTIVES The purpose of the present study was to evaluate whether magnetic resonance (MR) planimetry of the aortic valve area (AVA) may prove to be a reliable, non-invasive diagnostic tool in the assessment of aortic valve stenosis, and how the results compare with current diagnostic standards. BACKGROUND Current standard techniques for assessing the severity of aortic stenosis include transthoracic and transesophageal echocardiography (TEE) as well as transvalvular pressure measurements during cardiac catheterization. METHODS Forty consecutive patients underwent cardiac catheterization, TEE, and MR. The AVA was estimated by direct planimetry (MR, TEE) or calculated indirectly via the peak systolic transvalvular gradient (catheter). Pressure gradients from cardiac catheterization and Doppler echocardiography were also compared. RESULTS By MR, the mean AVA(max) was 0.91 +/- 0.25 cm(2); by TEE, AVA(max) was 0.89 +/- 0.28 cm(2); and by catheter, the AVA was calculated as 0.64 +/- 0.26 cm(2). Mean absolute differences in AVA were 0.02 cm(2) for MR versus TEE, 0.27 cm(2) for MR versus catheter, and 0.25 cm(2) for TEE versus catheter. Correlations for AVA(max) were r = 0.96 between MR and TEE, r = 0.47 between TEE and catheter, and r = 0.44 between MR and catheter. The correlation between Doppler and catheter gradients was r = 0.71. CONCLUSIONS Magnetic resonance planimetry of the AVA correlates well with TEE and less well with the catheter-derived AVA. Invasive and Doppler pressure correlated less well than those obtained from planimetric techniques. Magnetic resonance planimetry of the AVA may provide an accurate, non-invasive, well-tolerated alternative to invasive techniques and transthoracic echocardiography in the assessment of aortic stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of magnetic resonance imaging and cardiac catheterization in patients with suspected severe aortic stenosis.

OBJECTIVE Magnetic resonance imaging (MRI) is a novel technique used in the assessment of aortic stenosis. The aim of the study was to compare MRI and cardiac catheterization (CAT) that is still considered to be a "golden standard" in this indication. METHODS Thirty-four patients referred to CAT for the evaluation of aortic stenosis were enrolled into the study. CAT was performed according to...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

مقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران

Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...

متن کامل

Acquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent

Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2003