In vitro evaluation of positive expiratory pressure devices attached to nebulizers.

نویسنده

  • Ariel Berlinski
چکیده

BACKGROUND Patients with cystic fibrosis perform airway clearance techniques and receive nebulized medications on a regular basis. Some positive expiratory pressure (PEP) devices allow concomitant administration of aerosol. I hypothesized that this practice alters the aerosol characteristics and patient dose. I compared the aerosol characteristics and patient dose of nebulized albuterol from 2 types of nebulizer, alone and when connected to different PEP and vibratory PEP devices. METHODS Three units of a continuous-output nebulizer (Up-Draft II Opti-Neb) and 3 units of a breath-enhanced nebulizer (LC Plus) were tested alone and connected to PEP devices (Acapella Choice, Acapella Duet, and EzPAP for Up-Draft II Opti-Neb, and Pari PEP at 2 different settings, and Pari PEP S system with the LC Plus). Aerosol characteristics were evaluated with a cooled cascade impaction technique. The nebulizers were loaded with 2.5 mg/3 mL albuterol solution and operated for 4 min at 6 L/min (wall air). Patient dose was evaluated with simulated breathing patterns for a child, small adult, and large adult. Albuterol was assayed via spectrophotometry. RESULTS Connecting the LC Plus to the PEP devices did not change the aerosol characteristics or patient dose. Connecting the Up-Draft II Opti-Neb to the PEP devices significantly reduced the mass median aerodynamic diameter, from 4.13 μm to 3.72 μm with EzPAP (P = .02), 1.24 μm with Acapella Choice (P < .001), and 1.22 μm with Acapella Duet (P < .001). The total amount of albuterol captured by the impactor decreased when connected to either Acapella Choice (65%) or Acapella Duet (69%), with 17-25% retained in the PEP devices. Patient dose decreased by 76% and 84% when connected to Acapella Choice and Acapella Duet, respectively. CONCLUSIONS Concomitant use of nebulizer and PEP or vibratory PEP devices that obstruct the aerosol pathway significantly decrease the aerosol particle size and the patient dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

Device Cleaning and Infection Control in Aerosol Therapy.

Aerosol delivery equipment used to administer inhaled medications includes the nebulizer, positive expiratory pressure devices added to the nebulizer, and valved holding chambers (spacers). These devices are semi-critical medical devices, and as such, infection prevention and control (IPC) guidelines recommend that they be cleaned, disinfected, rinsed with sterile water, and air-dried. There is...

متن کامل

Impact of humidification and nebulization during expiratory limb protection: an experimental bench study.

BACKGROUND Different filtering devices are used during mechanical ventilation to avoid dysfunction of flow and pressure transducers or for airborne microorganisms containment. Water condensates, resulting from the use of humidifiers, but also residual nebulization particles may have a major influence on expiratory limb resistance. OBJECTIVES To evaluate the influence of nebulization and activ...

متن کامل

Positive Expiratory Pressure (PEP) versus Conventional Chest Physiotherapy in Pediatric Patients with Acute Exacerbation of Cystic Fibrosis

Background Pulmonary involvement is the main cause of mortality in cystic fibrosis (CF). Airway clearance techniques are non-pharmacological complement options for CF patients. The aim of this study was to evaluate the short-term outcome of airway cleaning treatment in patients with cystic fibrosis in a children's hospital. Materials and Methods This clinical trial study conducted on 40 CF pati...

متن کامل

Evaluation of a nanosuspension formulation prepared through microfluidic reactors for pulmonary delivery of budesonide using nebulizers

This study aimed to determine the aerosolization behavior of a nanodispersion of budesonide, prepared using microfluidic reactors. The size and morphology of budesonide nanoparticles were characterized by photon correlation spectroscopy (PCS) and transmission electron microscopy (TEM). Processing/formulation parameters for formation of the nanoparticles were studied to determine their effects o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 59 2  شماره 

صفحات  -

تاریخ انتشار 2014