Relative predictive value of lung cancer screening CT versus myocardial perfusion attenuation correction CT in the evaluation of coronary calcium

نویسندگان

  • Grant Bailey
  • Abigail Healy
  • Bryan D Young
  • Esseim Sharma
  • Judith Meadows
  • Hyung J Chun
  • Wen-Chih Wu
  • Gaurav Choudhary
  • Alan R Morrison
چکیده

Coronary artery calcium scores (CACS) from lung cancer screening computed tomography (LCSCT) or myocardial perfusion attenuation correction computed tomography (ACCT) are not routinely performed or reported. CACS from LCSCT and ACCT have not been directly compared in the same patient population. We identified 66 patients who underwent both LCSCT (non-gated) and ECG-gated cardiac CT (CCT) within a 2-year span. Of this population, 40 subjects had also undergone ACCT. Using the Agatston method, CACS for 264 individual vessels from the LCSCT population and for 160 vessels from ACCT population were calculated and evaluated for agreement with ECG-gated CCT as the gold standard. Secondary analysis included a comparison of individual vessel contribution to variations in agreement and a comparison of total CACS from CCT, LCSCT, and ACCT for respective MACE prediction. CACS from LCSCT demonstrated a strong Pearson correlation, r = 0.9017 (0.876-0.9223), with good agreement when compared to CACS from CCT. CACS from ACCT demonstrated a significantly (P < 0.00001) weaker correlation, r = 0.5593 (0.4401-0.6592). On an individual vessel basis, CACS from all major vessels (LM, LAD, LCX, and RCA) contributed to the weaker correlation. For total vessel CACS, LCSCT demonstrated comparable area under the curve (AUC) for the receiver operating characteristic (ROC) curve (LCSCT AUC = 0.8133 and CCT AUC = 0.8302, P = 0.691) for prediction of MACE. Although ACCT demonstrated a similar AUC (ACCT AUC = 0.7969, P = 0.662) for MACE prediction the cutoff value for elevated risk was extremely low. In conclusion, LCSCT outperformed ACCT at calcium scoring by providing better agreement and comparable risk assessment to CCT despite the absence of ECG-gating. It is therefore reasonable to use LCSCT images to derive and report Agatston-based CACS for cardiovascular risk assessment, whereas the use of ACCT images to report Agatston-based CACS is not currently practical.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies

Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

Coronary artery calcium (CAC) score – a prognostic tool in coronary artery disease?

Introduction: The aim of this study was to evaluate the impact of measurement of coronary artery calcification score (CAC) in patients with suspected coronary artery disease (CAD) and a normal myocardial perfusion scan. Methods: In a prospective study we measured the calcium score of 74 patients (29 m, 45 f, mean age 58.7 (m) and 64.4 (f)) with suspicion of CAD and a normal perfusion scan. In ...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017