Focusing polycapillary to reduce parasitic scattering for inelastic x-ray measurements at high pressure.

نویسندگان

  • P Chow
  • Y M Xiao
  • E Rod
  • L G Bai
  • G Y Shen
  • S Sinogeikin
  • N Gao
  • Y Ding
  • H-K Mao
چکیده

The double-differential scattering cross-section for the inelastic scattering of x-ray photons from electrons is typically orders of magnitude smaller than that of elastic scattering. With samples 10-100 μm size in a diamond anvil cell at high pressure, the inelastic x-ray scattering signals from samples are obscured by scattering from the cell gasket and diamonds. One major experimental challenge is to measure a clean inelastic signal from the sample in a diamond anvil cell. Among the many strategies for doing this, we have used a focusing polycapillary as a post-sample optic, which allows essentially only scattered photons within its input field of view to be refocused and transmitted to the backscattering energy analyzer of the spectrometer. We describe the modified inelastic x-ray spectrometer and its alignment. With a focused incident beam which matches the sample size and the field of view of polycapillary, at relatively large scattering angles, the polycapillary effectively reduces parasitic scattering from the diamond anvil cell gasket and diamonds. Raw data collected from the helium exciton measured by x-ray inelastic scattering at high pressure using the polycapillary method are compared with those using conventional post-sample slit collimation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Suppression of Bragg reflection glitches of a single-crystal diamond anvil cell by a polycapillary half-lens in high-pressure XAFS spectroscopy.

In combination with a single-crystal diamond anvil cell (DAC), a polycapillary half-lens (PHL) re-focusing optics has been used to perform high-pressure extended X-ray absorption fine-structure measurements. It is found that a large divergent X-ray beam induced by the PHL leads the Bragg glitches from single-crystal diamond to be broadened significantly and the intensity of the glitches to be r...

متن کامل

Experimental determination of the elasticity of iron at high pressure

[1] We present a multitechnique approach to experimentally determine the elastic anisotropy of polycrystalline hcp Fe at high pressure. Directional phonon measurements from inelastic X-ray scattering on a sample with lattice preferred orientation at 52 GPa in a diamond anvil cell were coupled with X-ray diffraction data to determine the elastic tensor. Comparison of the results from this new me...

متن کامل

Focusing Polycapillary Optics and Their Applications

A summary of focusing X ray polycapillary optics is presented including history, theory, modeling, and applications development. The focusing effects of polycapillary optics come from the overlap of the beams from thousands of small hollow glass tubes. Modeling efforts accurately describe optics performance to allow for system development in a wide variety of geometries. The focusing of X ray b...

متن کامل

Complete Data Sets Acquired with Different Polycapillary Optic - Source Configurations

The work described in this paper concerns a systematic study of the applications of both collimating and slightly focusing polycapillary optical systems to X-ray crystallographic structure determination of egg-white lysozyme using a standard rotating anode source and a low power tabletop microfocusing source. The results summarize a series of measurements comparing duplicate data sets obtained ...

متن کامل

Cost-effective upgrade of a focusing system for inelastic X-ray scattering experiments under high pressure

Inelastic X-ray scattering (IXS) is a powerful technique capable of probing the dynamic behavior and electronic structure of materials. For IXS experiments under high pressure up to the megabar range using state-of-the-art diamond-anvil-cell technology, the sample volume is limited to the order of 1 x 10(-3) mm(3) for which a beam focus of the same order and less is often required. In this pape...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 86 7  شماره 

صفحات  -

تاریخ انتشار 2015