Experiments on heating of low density CHO-foams by soft X-rays
نویسندگان
چکیده
Experiments, which use a combination of the PHELIX laser kJ-option and the heavy ion beam of 4-10 MeV/u energy delivered by the UNILACaccelerator, are aimed at investigation of the heavy ion energy loss in ionized matter. In these experiments a large scale (~1mm) long living (~5ns) high density plasma target with homogeneously distributed plasma density, temperature and ionization degree is required. The time is defined by the duration of the heavy ion bunch of 3 ns, the spatial size of the plasma target by the diameter of the heavy ion beam of ~ 0.5 mm. Highly homogeneous and slowly expanding plasma can be obtained when a low-density foam layer is volumetrically heated by soft X-rays. The indirectly heated laser target design for combined heavy ion beam laser experiments was proposed by Vatulin and Vasina [1]. In this scheme the laser interacts with the gold wall of the cylindrical converter (a primer hohlraum) where the laser energy is effectively converted into the soft X-rays with spectral distribution close to the Planckian one. Hohlraum generated X-rays heat volumetrically a lowdensity foam which serves as a plasma target for probing with heavy ion beams.
منابع مشابه
Effect of Joule-Heating Annealing on Giant Magnetoimpedance of Co64Fe4Ni2B19-xSi8Cr3Alx (x = 0, 1 and 2) Melt-Spun Ribbons
In this work, we have studied the influence of dc joule-heating thermal processing on the structure, magnetoimpedance (MI) and thermal properties of Co64Fe4Ni2B19-xSi8Cr3Alx (x = 0, 1, and 2) rapidly solidified melt-spun ribbons. The nanocrystallization process was carried out by the current annealing of as-spun samples at various current densities. As-spun and joule-heated samples were studied...
متن کاملLateral Soft Tissue X-ray for Patients with Suspected Fishbone in Oropharynx, A thing in the past
Introduction: Fishbone is the most common foreign body found in the oropharynx. Conventionally patients with suspected fishbone in the throat would have mirror laryngoscopy followed by lateral soft tissue X-ray to look for the fishbone or observe impacts caused by the fishbone i.e. soft tissue swelling or air in upper esophagus. However, the most common site of fishbone impact is the suprahyoid...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملThermal-insulation performance of low density polyethylene (LDPE) foams: Comparison between two radiation thermal conductivity models
The loss of energy especially in industrial and residential buildings is one of the main reasons of increased energy consumption. Improving the thermal insulation properties of materials is a fundamental method for reducing the energy losses. Polymeric foams are introduced as materials with excellent thermal insulation properties for this purpose. In the present study, a deep theoretical invest...
متن کاملTitle Multicomponent X-ray emissions from regions near or on the pulsar surface
We present a model of X-ray emission from rotation-powered pulsars, which in general consist of one nonthermal component, two hard thermal components, and one soft thermal component. The nonthermal X-rays come from synchrotron radiation of eB pairs created in the strong magnetic Ðeld near the neutron star surface by curvature photons emitted by charged particles on their way from the outer gap ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011