Comparison of immunoassays for semiquantitative measurement of benzoylecgonine in urine.
نویسندگان
چکیده
One way of monitoring the effectiveness of a treatment for cocaine addiction is to analyze a patient’s urine at regular intervals for benzoylecgonine (BE), the major metabolite of cocaine. Total absence of BE from the urine indicates that the patient has stopped using cocaine, while a significant reduction in the urinary concentration of BE indicates that the patient is using less cocaine, and therefore is receiving some benefit from the treatment. To determine if there has been a reduction in the amount of cocaine used, it is necessary to employ a quantitative, or at least semiquantitative, method of analysis. However, because many factors can affect the concentration of a drug or any of its metabolites in urine, determination of urine concentrations can only provide an approximate indication of the amount of drug recently introduced into the body.
منابع مشابه
Direct semiquantitative screening of drugs of abuse in serum and whole blood by means of CEDIA DAU urine immunoassays.
The purpose of this study was to test the direct applicability of CEDIA DAU urine immunoassays to serum or whole blood. The performance of the urine assays for sensitive screening of amphetamines (AMP), benzoylecgonine (BZE), benzodiazepines (BENZ), methadone (MET), opiates (OPI), and tetrahydrocannabinol carboxylic acid (THCCOOH) was evaluated on the BM/Hitachi 911 analyzer with unpretreated s...
متن کاملEvaluation of the radioimmunoassay for benzoylecgonine (a cocaine metabolite) in human urine.
The 125I-radioimmunoassay (RIA) for benzylecgonine (cocaine metabolite) in urine was evaluated by comparison with gas-liquid chromatography (GLC) and thin-layer chromatography (TLC) and the Enzyme-Multiplied Immunoassay Technique (EMIT). By RIA, a statistically significant concentration, 2 microng/liter, was observed for urinary benzoylecgonine. The coefficient of variation for the RIA was 2.58...
متن کاملPerformance characteristics of three automated immunoassays for thyroid hormones
Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...
متن کاملComparison of ELISA and TLC Methods for the Morphine Detection in Urine of Drug Abusers
Background: The current study was conducted to compare ELISA with thin layer chromatography (TLC) methods for diagnosis of morphine in the urine. Methods: Positive urine samples for morphine confirmed by immunochromatographic strips were collected from the Imam Reza Toxicology Laboratory, Mashhad University of Medical Sciences, Mashhad, Iran in 2012 for the current study. Then, the collated ...
متن کاملAnalytic performance of immunoassays for drugs of abuse below established cutoff values.
BACKGROUND The analytic performance and accuracy of drug detection below Substance Abuse and Mental Health Services Administration (SAMHSA) cutoffs is not well known. In some patient populations, clinically significant concentrations of abused drugs in urine may not be detected when current SAMHSA cutoffs are used. Our objectives were to define the precision profiles of three immunoassay system...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NIDA research monograph
دوره 175 شماره
صفحات -
تاریخ انتشار 1997