[Leak monitoring in noninvasive ventilation].

نویسندگان

  • C A Rabec
  • O Reybet-Degat
  • P Bonniaud
  • A Fanton
  • P Camus
چکیده

Nasal mask ventilation has been shown to be effective, but outcomes do not always match expectations because of mouth leaks, patient-ventilator asynchrony, or decreased upper airway patency. These developments are detected when they lead ultimately to circuit leaks that lower the effectiveness of ventilation through pressure loss, poor inspiratory triggering, and prolonged inspiratory time. The quality of sleep is affected, and adverse effects and treatment intolerance may arise. A number of ways to detect leaks and their practical consequences are proposed in this article. We applied 310 leak-detection procedures to 177 patients who had disappointing clinical, gasometric, or polysomnographic outcomes of ventilation. The leak-detection procedures varied according to the type of ventilation and the supposed underlying pathophysiological mechanism. Significant leaks were detected in 132 patients (76%); therapeutic changes were then prescribed to optimize outcomes. We present a practical method to apply in patients with suboptimal ventilation outcomes. If leaks can be detected during treatment, the probable cause of treatment failure can sometimes be established and possible pathophysiological mechanisms better understood. With this knowledge, it may be possible to improve ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating noninvasive ventilation using a monitoring system coupled to a ventilator: a bench-to-bedside study.

Empirically determined noninvasive ventilation (NIV) settings may not achieve optimal ventilatory support. Some ventilators include monitoring modules to assess ventilatory quality. We conducted a bench-to-bedside study to assess the ventilatory quality of the VPAPIII-ResLink (ResMed, North Ryde, Australia). We tested the accuracy of minute ventilation (MV) and leak calculations given by VPAPII...

متن کامل

A comparison of leak compensation in acute care ventilators during noninvasive and invasive ventilation: a lung model study.

BACKGROUND Although leak compensation has been widely introduced to acute care ventilators to improve patient-ventilator synchronization in the presence of system leaks, there are no data on these ventilators' ability to prevent triggering and cycling asynchrony. The goal of this study was to evaluate the ability of leak compensation in acute care ventilators during invasive and noninvasive ven...

متن کامل

Bronchodilator delivery during simulated pediatric noninvasive ventilation.

BACKGROUND Noninvasive ventilation (NIV) is usually applied using bi-level positive airway pressure devices, and many of these devices use a single-limb patient circuit with an integrated leak port to purge the circuit of exhaled carbon dioxide. Sometimes bronchodilator therapy is indicated in pediatric patients, but there have been no studies of the optimal nebulizer position, with respect to ...

متن کامل

Albuterol delivery during noninvasive ventilation.

HYPOTHESIS Albuterol delivered during noninvasive positive-pressure ventilation is affected by use of a nebulizer or metered-dose inhaler (MDI) and whether the leak port is in the hose or the mask. METHODS A lung model that simulated spontaneous breathing at 20 breaths/min was used. A bi-level positive-airway-pressure ventilator (Respironics S/T30) was set for an inspiratory positive airway p...

متن کامل

Ventilators for noninvasive ventilation to treat acute respiratory failure.

The application of noninvasive ventilation (NIV) to treat acute respiratory failure has increased tremendously both inside and outside the intensive care unit. The choice of ventilator is crucial for success of NIV in the acute setting, because poor tolerance and excessive air leaks are significantly correlated with NIV failure. Patient-ventilator asynchrony and discomfort can occur if the phys...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de bronconeumologia

دوره 40 11  شماره 

صفحات  -

تاریخ انتشار 2004