Heavy Silicone Oil and Intraocular Inflammation

نویسندگان

  • Francesco Morescalchi
  • Ciro Costagliola
  • Sarah Duse
  • Elena Gambicorti
  • Barbara Parolini
  • Barbara Arcidiacono
  • Mario R Romano
  • Francesco Semeraro
چکیده

In the past two decades, many advances have been made in vitrectomy instrumentation, surgical techniques, and the use of different tamponade agents. These agents serve close retinal breaks, confine eventual retinal redetachment, and prevent proliferative vitreoretinopathy (PVR). Long-acting gases and silicone oil are effective internal tamponade agents; however, because their specific gravity is lower than that of the vitreous fluid, they may provide adequate support for the superior retina but lack efficacy for the inferior retina, especially when the fill is subtotal. Thus, a specific role may exist for an internal tamponade agent with a higher specific gravity, such as heavy silicone oils (HSOs), Densiron 68, Oxane HD, HWS 45-300, HWS 46-3000, and HeavySil. Some clinical evidence seems to presume that heavy tamponades are more prone to intraocular inflammation than standard silicone if they remain in the eye for several months. In this review, we discuss the fundamental clinical and biochemical/molecular mechanisms involved in the inflammatory response after the use of heavy tamponade: toxicity due to impurities or instability of the agent, direct toxicity and immunogenicity, oil emulsification, and mechanical injury due to gravity. The physical and chemical properties of various HSOs and their efficacy and safety profiles are also described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interaction with intraocular lens materials: does heavy silicone oil act like silicone oil?

PURPOSE To determine the interaction of heavy silicone oil with various intraocular lens (IOL) materials and whether heavy silicone oil covers the silicone IOL optic as silicone oil does. SETTING Department of Ophthalmology, Dokuz Eylul University, Izmir, Turkey. METHODS The study group comprised 5 poly(methyl methacrylate) (PMMA) IOLs, 4 foldable silicone IOLs, 5 foldable hydrophilic acryl...

متن کامل

Anatomical and functional results of endotamponade with heavy silicone oil - Densiron 68 - in complicated retinal detachment.

BACKGROUND High-density silicone oils are newly developed long-term tamponade agents for the treatment of complicated retinal detachment in the inferior retina. Previous studies describe satisfying anatomical and functional results. In this study we examined the largest cohort so far for a 9-month follow-up and performed a comparison to conventional silicone oil. METHODS Our study documents r...

متن کامل

A comparison of retrokeratoprosthetic membrane and conjunctival inflammatory responses to silicone oil

Silicone oil continues to be an important aid in retinal detachment surgery. We report a case in which disparate responses to silicone oil were noted in the conjunctiva and intraocularly. Intraocularly, the oil permeated a fibrous membrane that formed behind a keratoprosthesis, the first example of this phenomenon. We detail the histological response to the oil at this site as well as a distinc...

متن کامل

Attenuation of iodine 125 radiation with vitreous substitutes in the treatment of uveal melanoma.

OBJECTIVE To demonstrate attenuation of radiation from iodine 125 ((125)I) to intraocular structures using liquid vitreous substitutes. METHODS Four candidate vitreous substitutes were tested for attenuation using empirical measurement and theoretical calculation. In vitro and ex vivo cadaveric dosimetry measurements were obtained with lithium fluoride thermoluminescent dosimeters to demonstr...

متن کامل

A case report of intraocular lens luxation with the capsular bag after vitrectomy.

We experienced a case of intraocular lens (IOL) luxation with the capsular bag after vitrectomy. The case was a 66-year-old female in whom an IOL was implanted one year after surgery for giant tear retinal detachment using silicone oil. Four years after the implantation surgery, the patient suffered subluxation of the IOL with the capsular bag. Examinations of the luxated IOL with the capsular ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014