Cervical spine movement during laryngoscopy with the Bullard, Macintosh, and Miller laryngoscopes.
نویسندگان
چکیده
BACKGROUND Direct laryngoscopy requires movement of the head, neck, and cervical spine. Spine movement may be limited for anatomic reasons or because of cervical spine injury. The Bullard laryngoscope, a rigid fiberoptic laryngoscope, may cause less neck flexion and head extension than conventional laryngoscopes. The purpose of this study was to compare head extension (measured externally), cervical spine extension (measured radiographically), and laryngeal view obtained with the Bullard, Macintosh, and Miller laryngoscopes. METHODS Anesthesia was induced in 35 ASA 1-3 elective surgery patients. Patients lay on a rigid board with head in neutral position. Laryngoscopy was performed three times, changing between the Bullard, Macintosh, and Miller laryngoscopes. Head extension was measured with an angle finder attached to goggles worn by the patient. The best laryngeal view with each laryngoscope was assessed by the laryngoscopist. In eight patients, lateral cervical spine radiographs were taken before and during laryngoscopy with the Bullard and Macintosh blades. RESULTS Median values for external head extension were 11 degrees, 10 degrees, and 2 degrees with the Macintosh, Miller, and Bullard laryngoscopy (P < 0.01), respectively. Significant reductions in radiographic cervical spine extension were found for the Bullard compared to the Macintosh blade at the atlantooccipital joint, atlantoaxial joint, and C3-C4. Median atlantooccipital extension angles were 6 degrees and 12 degrees for the Bullard and Macintosh laryngoscopes, respectively. The larynx could be exposed in all patients with the Bullard but only in 90% with conventional laryngoscope (P < 0.01). CONCLUSIONS The Bullard laryngoscope caused less head extension and cervical spine extension than conventional laryngoscopes and resulted in a better view. It may be useful in care of patients in whom cervical spine movement is limited or undesirable.
منابع مشابه
مقایسه لارنگوسکوپ میلر و مکین تاش در خارج سازی جسم خارجی از ناحیه هیپوفارنکس به کمک پنس مگیل
Abstract: Aims and Background: Esophageal foreign body can be harmful. Esophagoscopy is the most common method of foreign body extraction. But in many cases during laryngoscopy the foreign body is visible in hypopharynx region and anesthesiologist can remove it with a Magill forceps. In these cases laryngoscopy should give an appropriate and sufficient view from hypopharynx. The aim of this st...
متن کاملConfidence in statistical analysis.
1 Smith CE, Sidhu TS, Lever J, Pinchak AB. The complexity of tracheal intubation using rigid ®beroptic laryngoscopy (WuScope). Anesth Analg 1999; 89: 236±9 2 Smith CE, Boyer D. Cricoid pressure decreases ease of tracheal intubation using ®breoptic laryngoscopy (WuScope System). Can J Anaesth 2002; 49: 614±19 3 Levitan RM, Kush S, Hollander JE. Devices for dif®cult airway management in academic ...
متن کاملCervical spine motion: a fluoroscopic comparison of the AirTraq Laryngoscope versus the Macintosh laryngoscope.
BACKGROUND The optimal technique to intubate the trachea in patients presenting with a potential or documented cervical spine (C-spine) injury remains unresolved. Using continuous fluoroscopic video assessment, C-spine motion during laryngoscopy with an AirTraq Laryngoscope (King Medical Systems, Newark, DE) was compared to that with intubation using a Macintosh blade. METHODS Twenty-four hea...
متن کاملA comparison of McCoy, TruView, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine
BACKGROUND Cervical spine immobilization results in a poor laryngeal view on direct laryngoscopy leading to difficulty in intubation. This randomized prospective study was designed to compare the laryngeal view and ease of intubation with the Macintosh, McCoy, and TruView laryngoscopes in patients with immobilized cervical spine. MATERIALS AND METHODS 60 adult patients of ASA grade I-II with ...
متن کاملIntubation biomechanics: laryngoscope force and cervical spine motion during intubation with Macintosh and Airtraq laryngoscopes.
INTRODUCTION Laryngoscopy and endotracheal intubation in the presence of cervical spine instability may put patients at risk of cervical cord injury. Nevertheless, the biomechanics of intubation (cervical spine motion as a function of applied force) have not been characterized. This study characterized and compared the relationship between laryngoscope force and cervical spine motion using two ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 82 4 شماره
صفحات -
تاریخ انتشار 1995