A comparative study of bone densitometry during osseointegration: piezoelectric surgery versus rotary protocols.

نویسندگان

  • Luca Di Alberti
  • Federica Donnini
  • Claudio Di Alberti
  • Michele Camerino
چکیده

OBJECTIVES To date, there have been no studies on the outcome of osseointegration of alveolar bone around dental implants inserted with piezoelectric osteotomy versus conventional osteotomy. The aim of this study was to compare the radiographic differences, through evaluation of peri-implant bone density, between implant insertion using traditional surgical technique and piezoelectric technique. METHOD AND MATERIALS Forty patients were selected whose treatment consisted of a minimum of two implants placed in nonpathologic native bone. A single type of implant surface (SLA) was chosen. The implants were placed following the manufacturer protocol for traditional surgical technique and piezoelectric technique. Radiographs were taken following surgery and 30, 60, and 90 days after surgery. The bone density was studied with the densitometry application. RESULTS AND CONCLUSION All patients completed the study period with success. Despite a limited number of treated patients, the results of this pilot study demonstrated that (1) piezoelectric implant site preparation promotes better bone density and osteogenesis, and (2) the piezoelectric technique is predictable, with a 100% success rate in this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Implant Site Preparation by Piezoelectric and Conventional Drilling on Autograft Cell Viability: A Clinical Trial

Background and Aim: Implant site preparation with minimal trauma is an important factor in success of implant treatment and has a great effect on osseointegration. Piezoelectric bone surgery was introduced as a modern technique for micrometric osteotomy with precise, controllable action. Preservation of osteoblast cell viability is critical to achieve successful osseointegration. The present st...

متن کامل

Cytokines and growth factors involved in the osseointegration of oral titanium implants positioned using piezoelectric bone surgery versus a drill technique: a pilot study in minipigs.

BACKGROUND Most dental implants are positioned using a drilling surgery technique. However, dentistry recently experienced the implementation of piezoelectric surgery. This technique was introduced to overcome some of the limitations involving rotating instruments in bone surgery. This study used biomolecular and histologic analyses to compare the osseointegration of porous implants positioned ...

متن کامل

Cytokines and Growth Factors Involved in the Osseointegration of Oral Titanium Implants Positioned using Piezoelectric Bone Surgery Versus a Drill Technique: A Pilot Study in Minipigs

Statement: Osteotomies are well-established procedures in oral and maxillofacial surgery for either corrective measures or for gaining access to subjacent hard and soft tissues. Yet surgical reconstruction of bony defects can often be very challenging as thin and fragile bony structures are especially prone to fracture due to bulky cutting tips or massive application of pressure by conventional...

متن کامل

Comparative Study of Piezoelectric and Rotary Osteotomy Technique for Third Molar Impaction.

INTRODUCTION Bone removal is necessary for extracting the third molars that are erupted, partially erupted, and/or impacted in bone. Hence, it is necessary to choose a surgical method or instruments that conform to anatomic landmarks and are based on physiological principles. Many authors have reported injuries to the adjacent tooth, especially the distal part of periodontium after removal of s...

متن کامل

A comparative study of “plasmacup” and “porous‐coated” acetabular components: survival after 10 to 12 years of follow‐up

OBJECTIVES Our primary aim was to compare the long-term survivorship rates and the rates of successful osseointegration between two different types of uncemented acetabular components. INTRODUCTION Two types of alloys have primarily been used for the manufacture of the uncemented acetabular components: titanium-based and cobalt-based alloys. A titanium-based alloy appears to be more effective...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Quintessence international

دوره 41 8  شماره 

صفحات  -

تاریخ انتشار 2010