Customer-side SCADA-assisted Large Battery Operation Optimization for Distribution Feeder Peak Load Shaving

نویسندگان

  • Zach Taylor
  • Hossein Akhavan-Hejazi
  • Ed Cortez
  • Lilliana Alvarez
چکیده

Built upon real-world SCADA and other measurements of a featured utility-scale testbed, this paper addresses the participation of customer side battery energy storage in providing peak load shaving at a 12.47 kV distribution feeder. A stochastic optimization-based battery operation framework is developed that enables feeder load peak shaving under offline (day-ahead) as well as online (close-to-real-time) control settings. Both designs work through establishing a secured communications line to the utility’s feeder-level SCADA system. Multiple field experiments are conducted, including a full day test with complete control of a 1 MWh / 200 kW battery system, as well as various numerical assessments based upon one year of real feeder data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Locating, Sizing, and Optimal Planning of the Distribution Substations Using Vanadium Flow Battery Storage to Improve the Efficiency of the Power Distribution Network

In power grids, there must always be a balance between energy production and consumption. Due to the variable nature of consumers, energy production should also be subject to these changes. Electricity storage is one of the most important issues in the electricity industry, which can generate many ancillary services such as load curve leveling, peak shaving, integration with renewable units, ro...

متن کامل

Controllable Load Management Approaches in Smart Grids

With rapid smart grid technology development, the customer can actively participate in demand-side management (DSM) with the mutual information communication between the distributor operation company and the smart devices in real-time. Controllable load management not only has the advantage of peak shaving, load balance, frequency regulation, and voltage stability, but is also effective at prov...

متن کامل

Using Battery Storage for Peak Shaving and Frequency Regulation: Joint Optimization for Superlinear Gains

We consider using a battery storage system simultaneously for peak shaving and frequency regulation through a joint optimization framework which captures battery degradation, operational constraints and uncertainties in customer load and regulation signals. Under this framework, using real data from a Microsoft data center, an University of Washington building and PJM, we show the electricity b...

متن کامل

Grid-supporting Battery Energy Storage Systems in the Low-voltage Distribution Grid

The integration of renewable energy sources into the distribution grid may cause more profound voltage deviations and overloading of grid elements. In certain countries (for example, Belgium), a lot of photovoltaic systems are connected to the low-voltage distribution grid at household residences. These renewable energy sources may cause excessive voltage increase at times when also the load is...

متن کامل

Load peak shaving and power smoothing of a distribution grid with high renewable energy penetration

High penetration of renewable energy poses a significant challenge in operation of power system. A potential solution for this problem is utilizing Battery Energy Storage System (BESS). The purpose of this paper is to analyze the effectiveness of BESS ability to peak shave and smooth the load curve of an actual circuit on the island of Maui in Hawaii. The distribution circuit has about 850 kW o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017