Error Estimates for Calculated Glomerular Filtration Rates
نویسنده
چکیده
Glomerular filtration rate (GFR) is a measure of kidney function. It is usually estimated from serum concentrations of cystatin C or creatinine although there has been considerable debate in the literature about (i) the best equation to use and (ii) the variability in the correlation between the concentrations of creatinine and cystatin C. The equations for GFR can be written in a general form and from these I calculate the error of the GFR estimates associated with analyte measurement error. These show that the error of the GFR estimates is such that it is not possible to distinguish between the equations over much of the concentration range of either analyte. The general forms of the equations are also used to derive an expression for the concentration of cystatin C as a function of the concentration of creatinine. This equation shows that these analyte concentrations are not linearly related. Clinical reports of cystatin C and creatinine concentration are consistent with the expression derived. Keywords—creatinine, cystatin C, error analysis, glomerular filtration rate, measurement error.
منابع مشابه
Enzymatic creatinine assays allow estimation of glomerular filtration rate in stages 1 and 2 chronic kidney disease using CKD-EPI equation.
The National Kidney Disease Education Program group demonstrated that MDRD equation is sensitive to creatinine measurement error, particularly at higher glomerular filtration rates. Thus, MDRD-based eGFR above 60 mL/min/1.73 m² should not be reported numerically. However, little is known about the impact of analytical error on CKD-EPI-based estimates. This study aimed at assessing the impact of...
متن کاملValidity of estimated glomerular filtration rates for assessment of baseline and serial renal function in patients with atherosclerotic renal artery stenosis: implications for clinical trials of renal revascularization.
BACKGROUND Despite routine use of estimated glomerular filtration rates (GFRs) as major renal end points in clinical trials of renal revascularization, serial GFR estimates have never been validated in patients with renal artery stenosis (RAS). The purpose of this study was to evaluate the validity of GFR estimates in patients with atherosclerotic RAS. METHODS AND RESULTS Serum creatinine (SC...
متن کاملAre glomerular filtration rate estimations necessary before high dose methotrexate?
Glomerular filtration rates (GFR) were estimated in 168 children (227 estimates) before treatment for haematological malignancies with high dose, intravenous methotrexate. Clinical management was altered on the basis of GFR in only two cases, both of whom had tumour lysis syndrome. Routine estimations of GFR do not contribute to management.
متن کاملStructural basis for reduced glomerular filtration capacity in nephrotic humans.
Previous studies have established that in a variety of human glomerulopathies the reduced glomerular filtration rate (GFR) is due to a marked lowering of the ultrafiltration coefficient (Kf). To identify the factors which lower Kf, we measured the filtering surface area per glomerulus, filtration slit frequency, basement membrane thickness, and GFR and its determinants in patients with minimal ...
متن کاملImprecision of urinary iothalamate clearance as a gold-standard measure of GFR decreases the diagnostic accuracy of kidney function estimating equations.
BACKGROUND Evaluating the accuracy of estimated glomerular filtration rate (eGFR) derived from serum creatinine (SCr) and serum cystatin C (SCysC) equations requires gold-standard measures of GFR. However, the influence of imprecise measured GFRs (mGFRs) on estimates of equation error is unknown. STUDY DESIGN Diagnostic test study. SETTING & PARTICIPANTS 1,995 participants from the Modifica...
متن کامل