Updating of HIMAC beam delivery with broad beam method

نویسندگان

  • Manabu Mizota
  • Shigekazu Fukuda
چکیده

Carbon ion radiotherapy at HIMAC started in 1994 using two horizontal and two vertical beam ports with broad beam method. The maximum beam energy extracted from accelerators was 400 MeV/n for the horizontal beam port, and 350 MeV/n for the vertical one. In recent years, the scope of diseases that can be treated by the carbon ion radiotherapy has widened and their tumor targets have varied in dimension and location. So, situations of shortage in the beam range in treatment planning have increased. In order to provide sufficient dose to the deeply seated target, we adopted higher energy beam, that is, 430 and 400 MeV/n for the horizontal port and the vertical port, respectively. For the introduction of the new energy beams, we carried out the following.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synchrotron Control System of Himac

HIMAC, Heavy Ion Medical Accelerator in Chiba, has been in operation for about 8 years. The control system of HIMAC synchrotron is now undergoing renewal and upgrade. As a medical accelerator in use, reliability and availability of the beam must not be compromised in HIMAC. We decided to change most computers of the system in a node-by-node way, over a couple of years. Among the replaced are: P...

متن کامل

Test Results of a Fast Beam Chopper with Ma Cores

A new type of fast beam chopper was developed and installed at the HIMAC facility. Test operations of the chopper have been carried out. The chopper is basically a periodic beam-energy transformer that performs 10% modulation of beam’s kinetic energy. The modulated fraction of the beam is chopped off by the downstream RFQ due to the relatively narrow injection energy window of the RFQ. Some of ...

متن کامل

Beam Control in the Spot Scanning Irradiation

Secondary beam course and its irradiation system have been constructed in HIMAC. In this system, positron emitter beam can be used to measure the irradiated volume with PET. As an irradiation method to use beam efficiently, the spot scanning irradiation was adopted. With this spot scanning system, irradiation test has been done with C beam. In this paper, the current status of the beam control ...

متن کامل

Status Report of the HIMAC Control System --Reliable beam supply for cancer radiotherapy with carbon beam--

HIMAC has been in operation for nearly two years. During this period, the accelerator complex was commissioned, clinical trial started June 1994, and more than fifty patients treated with a 290 400 MeV/u carbon beam, which has been delivered on schedule and with greater than 99% reliability.

متن کامل

The First Beam Acceleration Test Using High Gradient Cavity at Himac

The HGC loaded with MA cores has been developed[1] for the JHF (Japan Hadron Facility) proton synchrotrons. The maximum voltage of 20 kV has been obtained by the cavity of 40 cm in length. The cavity was driven by a pushpull amplifier using two 150 kW tetrodes. The frequency sweeping from 1 to 5 MHz has been achieved without any tuning circuit because of its broadband characteristics of the MA-...

متن کامل