δ13C analysis of amino acids in human hair using trimethylsilyl derivatives and gas chromatography/combustion/isotope ratio mass spectrometry.
نویسندگان
چکیده
RATIONALE To provide a simple one-step derivatization procedure for the analysis of a wide variety of amino acids in human hair by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). N,O-Bis(trimethylsilyl)trifluoroacetamide (BSTFA) derivatization is already widely used outside the IRMS community, is applicable to a variety of functional groups, and provides products that are common entries in mass spectral databases, thus simplifying compound identification. METHODS Method optimization and validation were performed on a mixture of ten standard amino acids found abundantly in human hair. The method was then applied to the analysis of scalp hair from six human subjects. The hair was washed, hydrolyzed with 6 M HCl, derivatized using BSTFA in acetonitrile and analyzed using gas chromatography (GC) with concurrent quadrupole and isotope ratio mass spectrometry (IRMS) detectors. RESULTS The reproducibility for the δ(13)C measurements, including the derivatization procedure and GC/C/IRMS analysis, on a day-to-day comparison was between 0.19‰ and 0.35‰ (SD, N = 12), with an average standard deviation of 0.26‰. Because trimethylsilylation adds 3N carbon atoms (where N = # reactive protons) to each amino acid, the δ(13)C values for amino acid derivatives were corrected using a mass balance correction and the measured kinetic isotope effect (KIE). The KIE values ranged from 0.984 to 1.020. CONCLUSIONS The procedure gave consistent δ(13)C values with precision similar to other derivatization methods for the range of sample sizes studied: 50-1000 µg of each amino acid. The method gave δ(13)C values consistent with the known literature values when applied to the analysis of amino acids in human hair.
منابع مشابه
Cometary glycine detected in samples returned by Stardust
available online at http://meteoritics.org Cometary glycine detected in samples returned by Stardust Jamie E. ELSILA*, Daniel P. GLAVIN, and Jason P. DWORKIN NASA Goddard Space Flight Center, Greenbelt, Maryland 20771, USA *Corresponding author: [email protected] (Received 05 June 2009; revision accepted 24 July 2009) Abstract–Our previous analysis of cometary samples returned to Earth by N...
متن کاملNitrogen isotopic analyses by isotope-ratio-monitoring gas chromatography / mass spectrometry.
Amino acids containing natural-abundance levels of (15)N were derivatized and analyzed isotopically using a technique in which individual compounds are separated by gas chromatography, combusted on-line, and the product stream sent directly to an isotope-ratio mass spectrometer. For samples of N2 gas, standard deviations of ratio measurement were better than 0.1‰ (Units for δ are parts per thou...
متن کاملDetermination of testosterone:epitestosterone ratio after pentafluorophenyldimethylsilyl-trimethylsilyl derivatisation using gas chromatography-mass spectrometry in equine urine.
A highly specific method is described for measuring the testosterone:epitestosterone ratio in equine urine by gas chromatography-mass spectrometry (GC-MS) with stable isotope internal standards. The procedure was based on Serdolit Pad-1 resin extraction, enzymatic hydrolysis, and chemical derivatisation prior to instrumental analysis. The mixed derivatives, 3-trimethylsilyl-17-pentafluorophenyl...
متن کاملDevelopment and Validation of a GC-FID Method for Diagnosis of Methylmalonic Acidemia
Background: Urinary organic acids are water-soluble intermediates and end products of the metabolism of amino acids, carbohydrates, lipids, and a number of other metabolic processes. In the hereditary diseases known as organic acidurias, an enzyme or co-factor defect in a metabolic pathway leads to the accumulation and increased excretion of one or more of these acidic metabolites. Gas chromato...
متن کاملIsotope-Dilution Mass Spectrometry for Quantification of Urinary Active Androgens Separated by Gas Chromatography
Cross reacting antibodies can cause an overestimation of the results of immunoassays. Therefore, alternative methods are needed for the accurate quantification of steroids. Gas chromatography combined with isotope-dilution mass spectrometry (GC-IDMS) is developed to quantify urinary active androgens, testosterone, epitestosterone and dihydrotestosterone, which are clinically relevant androgens ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 27 13 شماره
صفحات -
تاریخ انتشار 2013