Adverse effects of nasal continuous positive airway pressure therapy in sleep apnoea syndrome.
نویسندگان
چکیده
Nasal continuous positive airway pressure (nCPAP) is now the treatment of choice for patients with sleep apnoea syndrome. Side-effects and adverse reactions have been described in isolated reports with this device. We have, therefore, systematically studied the side-effects of nCPAP therapy in 300 consecutive patients referred to the London Chest Hospital Ventilatory Support Unit. Ninety-six per cent of patients complained of at least one side-effect resulting from the therapy, with 45 per cent complaining of a side-effect specific to the nasal mask. There was no correlation between the side-effects and level of pressure used during nCPAP. The rate of compliance remained high in spite of the side-effects, with a daily use of 7.8 hours (SD 8.05) and with 83 per cent of the patients using the device every night. Although nCPAP treatment remains acceptable to most patients there exists a high incidence of adverse effects.
منابع مشابه
Simultaneous sleep study and nasoendoscopic investigation in a patient with obstructive sleep apnoea syndrome refractory to continuous positive airway pressure: a case report
INTRODUCTION The standard treatment for obstructive sleep apnoea syndrome is nasal continuous positive airway pressure. In most cases the obstruction is located at the oropharyngeal level, and nasal continuous positive airway pressure is usually effective. In cases of non-response to nasal continuous positive airway pressure other treatments like mandibular advancement devices or upper airway s...
متن کاملComparison of Nasal Continuous Positive Airway Pressure Therapy with and without Prophylactic Surfactant in Preterm Neonates
Background: Preterm labor is at risk for respiratory distress syndrome (RDS) and sometimes requires to mechanical ventilation (MV) and surfactant therapy. Continuous positive airway pressure (CPAP) and Nasal Continuous positive airway pressure (NCPAP) are the methods of respiratory support especially for using in RDS of neonates. In other method surfactant is administered to babies via tracheal...
متن کاملHumidified nasal continuous positive airway pressure in obstructive sleep apnoea.
Heated humidification of nasal continuous positive airway pressure (nCPAP) reduces upper airway symptoms and improves initial use in obstructive sleep apnoea syndrome (OSAS). The present study aimed to assess the effect of heated humidification of nCPAP on upper airway symptoms and initial use in obstructive sleep apnoea. This study was of a randomised, crossover design. Subjects with polysomno...
متن کاملHaemodynamic effects of short-term nasal continuous positive airway pressure therapy in sleep apnoea syndrome: monitoring by a finger arterial pressure device.
We have evaluated the effects of short-term nasal continuous positive airway pressure (nCPAP) therapy on systemic blood pressure and heart rate in patients with obstructive sleep apnoea syndrome. Twenty five consecutive patients were examined during baseline conditions (No-CPAP) and during one night of nCPAP treatment (CPAP). The mean value and the variation coefficient of cardiovascular variab...
متن کاملResolution of obstructive sleep apnoea with growth in the Robin sequence.
A 12 year old female with the Robin sequence presented with a one year history of snoring, witnessed apnoeas and daytime sleepiness. Surgery in early childhood had consisted of cleft palate repair, tonsillectomy and adenoidectomy and, later, revision palatoplasty. Overnight polysomnography (PSG) demonstrated severe obstructive sleep apnoea syndrome with an apnoea/hypopnoea index (AHI) of 49 eve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of laryngology and otology
دوره 113 10 شماره
صفحات -
تاریخ انتشار 1999