Accuracy of dipstick urinalysis as a screening method for detection of glucose, protein, nitrites and blood.
نویسنده
چکیده
This study determined the reliability of dipstick urinalysis for detection of protein, glucose, blood and nitrites in non-random urine samples from 300 people aged > 50 years attending a health centre for check-up. The gold standards were fasting blood glucose for glucosuria and the sulfosalicylic acid method for urine protein. Microscopic examination of urinary sediment and urine culture were also performed for positive dipstick results for haematuria and nitrites. The sensitivity, specificity and positive and negative predictive values of the dipstick test for detection of protein were 80.0%, 95.0%, 22.2% and 99.6% and for glucose were 100%, 98.5%, 87.0% and 100% respectively. Dipstick urinalysis can be a reliable screening method for diagnosis of urinary tract infection and diabetes mellitus but not for proteinuria.
منابع مشابه
Evaluation of the leukocyte esterase and nitrite urine dipstick screening tests for detection of bacteriuria in women with suspected uncomplicated urinary tract infections.
A positive dipstick urinalysis (i.e., leukocyte esterase test and/or nitrite test) did not reliably detect significant bacteriuria in 479 ambulatory women with suspected uncomplicated urinary tract infection; 18.9% of the urine samples that demonstrated significant bacteriuria would have been rejected by the laboratory based on a negative urinalysis screen.
متن کاملAccuracy of urinalysis in detection of urinary tract infection in a primary care setting
Aim : To determine the accuracy of urinalysis in the detection of urinary tract infection (UTI) in symptomatic patients at primary care level. Methods : A cross sectional study was undertaken on 100 patients with symptoms of UTI presenting at the Primary Care Clinic of University Malaya Medical Center, Kuala Lumpur, Malaysia during the months of August to November 1999. Their urine samples were...
متن کاملCommunity EM Emergency department visual urinalysis versus laboratory urinalysis
Objective: The primary objective of this study was to compare the results of nurse-performed urinalysis (NPU) interpreted visually in the emergency department (ED) with laboratoryperformed urinalysis (LPU) interpreted by reflectance photometry. Methods: This was a prospective observational study based on a convenience sample from my emergency practice. Emer gency nurses, who were unaware of the...
متن کاملIdentifying high and low serum-ascites albumin gradient in ascitic fluid by the point of care dipstick test
Objective: To evaluate the capability of ascitic fluid dipstick results for pH, glucose, and protein in order to predict a low serum-ascites albumin gradient (SAAG) at the bedside of the patient in the emergency department (ED). Methods: This prospective cross-sectional study was conducted during one year in the ED of Afzalipour hospital in Kerman, Iran. ...
متن کاملThe Value of Urinalysis in Detection of Abdominal Organ Injuries in Children with Hematuria Following Blunt Abdominal Trauma; A Diagnostic Study
Background Currently, almost all patients with probable abdominal injury undergo urinalysis in emergency department (ED). The present survey was conducted with the aim of assessing the diagnostic values of urinalysis compare with abdominal computed tomography (CT) scan with contrast for predicting possible intra-abdominal injuries in children affected by blunt trauma. Materials and Methods: The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Eastern Mediterranean health journal = La revue de sante de la Mediterranee orientale = al-Majallah al-sihhiyah li-sharq al-mutawassit
دوره 15 5 شماره
صفحات -
تاریخ انتشار 2009