Automatic Mirror Alignment for VIRGO: First experimental demonstration of the Anderson technique on a large-scale interferometer
نویسندگان
چکیده
The French-Italian interferometric gravitational wave detector VIRGO is currently being commissioned. Its principal instrument is a Michelson laser interferometer with 3 km long optical cavities in the arms and a power-recycling mirror. The interferometer resides in an ultra-high vacuum system and the mirrors are suspended from multistage pendulums for seismic isolation. This type of laser interferometer reaches its maximum sensitivity only when the optical setup is held actively very accurately at a defined operating point: control systems using the precise interferometer signals stabilise the longitudinal and angular positions of the optical component. This paper gives an overview of the control system for the angular degrees of freedom; we Send correspondence to A. Freise, E-mail: [email protected] present the current status of the system and report the first experimental demonstration of the Anderson technique on a largescale interferometer.
منابع مشابه
ar X iv : g r - qc / 0 40 61 23 v 1 3 0 Ju n 20 04 Status of VIRGO *
The French-Italian interferometric gravitational wave detector VIRGO is currently being commissioned. Its principal instrument is a Michelson interferometer with 3 km long optical cavities in the arms and a powerrecycling mirror. This paper gives an overview of the present status of the system. We report on the presently attained sensitivity and the system’s performance during the recent commis...
متن کاملar X iv : g r - qc / 9 61 10 27 v 1 1 1 N ov 1 99 6 Alignment procedure for the VIRGO Interferometer : experimental results from the Frascati prototype
A small fixed-mirror Michelson interferometer has been built in Frascati to experimentally study the alignment method that has been suggested for VIRGO. The experimental results fully confirm the adequacy of the method. The minimum angular misalignment that can be detected in the present setup is 10 nrad/ √ Hz.
متن کاملThe variable finesse locking technique
Virgo is a power recycled Michelson interferometer, with 3 km long Fabry– Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good f...
متن کاملar X iv : g r - qc / 0 10 51 10 v 1 2 8 M ay 2 00 1 Inertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection
interferometric gravitational wave detectors must be isolated from seismic noise. The VIRGO vibration isolator, called superattenuator, is fully effective at frequencies above 4 Hz. Nevertheless, the residual motion of the mirror at the mechanical resonant frequencies of the system are too large for the interferometer locking system and must be damped. A multidimensional feedback system, using ...
متن کاملInertial control of the mirror suspensions of the VIRGO interferometer for gravitational wave detection
interferometric gravitational wave detectors must be isolated from seismic noise. The VIRGO vibration isolator, called superattenuator, is fully effective at frequencies above 4 Hz. Nevertheless, the residual motion of the mirror at the mechanical resonant frequencies of the system are too large for the interferometer locking system and must be damped. A multidimensional feedback system, using ...
متن کامل