Dependence of the pullout behaviour of pedicle screws on the screw-hosting material relative deformability
نویسندگان
چکیده
Indications exist in literature that a screw's pullout behaviour is among others influenced by the relative deformability of the screw and its hosting material. In addition it is known that the stress field developed in the vicinity of an orthopaedic implant significantly influences bone remodelling. In this context an experimentally validated finite element model of a screw and its hosting material was employed for the study of the pullout phenomenon. The results indicated that the stress distribution within the screw's hosting material is strongly influenced by the ratio of the screw's elastic modulus over the respective one of its hosting material. In addition it is concluded that an optimum value of this ratio exists for which the stresses are more uniformly distributed along the length of the screw improving this way the pullout behaviour, and therefore the overall mechanical response, of the “screw-hosting material” complex.
منابع مشابه
A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model.
The present study aims to the design of a finite-element model simulating accurately the pullout behaviour of cylindrical pedicle screws and predicting their pullout force. Three commercial pedicle screws, subjected to pure pullout from synthetic bone, were studied experimentally. The results were used for the design, calibration and validation of a finite-element model. Special attention was p...
متن کاملComparison and prediction of pullout strength of conical and cylindrical pedicle screws within synthetic bone
BACKGROUND This study was designed to derive the theoretical formulae to predict the pullout strength of pedicle screws with an inconstant outer and/or inner diameter distribution (conical screws). For the transpedicular fixation, one of the failure modes is the screw loosening from the vertebral bone. Hence, various kinds of pedicle screws have been evaluated to measure the pullout strength us...
متن کاملThe Comparison of Pullout Strengths of Various Pedicle Screw Designs on Synthetic Foams and Ovine Vertebrae.
AIM One of the most common problems with transpedicular screws is screw pullout. This study was conducted to measure the pullout strengths of newly designed transpedicular screws. MATERIAL AND METHODS The design of the three group screws were conical cored standard pedicle screw (Type A), dual threaded pedicle screw (Type B), dual core and dual threaded pedicle screw (Type C), respectively. P...
متن کاملThe Pullout Strength of Pedicle Screws Following Redirection After Lateral Wall Breach or End-plate Breach.
STUDY DESIGN Using fresh cadavers, the biomechanical testing were used to examine the pullout strength of each pedicle screw. OBJECTIVE The aim of this study was to evaluate pullout strength of (1) a redirected pedicle screw following lateral wall breach; (2) a redirected pedicle screw following end-plate breach; and (3) a pedicle without redirection after end-plate breach without redirection...
متن کاملPossible usage of cannulated pedicle screws without cement augmentation
BACKGROUND: The use of pedicle screws is becoming increasingly popular for spinal surgery practice as the technology advances. Screw pullout due to bone quality and loading conditions is one of the most common problems observed after pedicle screw fixation. Several solutions were studied to prevent screw pullout. These can be investigated under three main categories: screw design, expandable sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IJCAET
دوره 5 شماره
صفحات -
تاریخ انتشار 2013