Sustained prediction ability of net analyte preprocessing methods using reduced calibration sets. Theoretical and experimental study involving the spectrophotometric analysis of multicomponent mixtures.

نویسندگان

  • H C Goicoechea
  • A C Olivieri
چکیده

A newly developed multivariate method involving net analyte preprocessing (NAP) was tested using central composite calibration designs of progressively decreasing size regarding the multivariate simultaneous spectrophotometric determination of three active components (phenylephrine, diphenhydramine and naphazoline) and one excipient (methylparaben) in nasal solutions. Its performance was evaluated and compared with that of partial least-squares (PLS-1). Minimisation of the calibration predicted error sum of squares (PRESS) as a function of a moving spectral window helped to select appropriate working spectral ranges for both methods. The comparison of NAP and PLS results was carried out using two tests: (1) the elliptical joint confidence region for the slope and intercept of a predicted versus actual concentrations plot for a large validation set of samples and (2) the D-optimality criterion concerning the information content of the calibration data matrix. Extensive simulations and experimental validation showed that, unlike PLS, the NAP method is able to furnish highly satisfactory results when the calibration set is reduced from a full four-component central composite to a fractional central composite, as expected from the modelling requirements of net analyte based methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Spectrophotometric Determination of Heavy Metal Ions Using Several Chemometrics Methods: Effect of Different Parameters of Savitzky-Golay and Direct Orthogonal Signal Correction Filters

Direct orthogonal signal correction(DOSC) and Savitzky-Golay filters (SGF) were applied as preprocessing methods on the original and first derivative absorbance data. Principle component regression (PCR), partial least squares (PLS) and iterative target transformation factor analysis (ITTFA), were used in spectrophotometric simultaneous determination of heavy divalent metal ions, l...

متن کامل

Resolving Spectra Overlapping Based on Net Analyte Signal for Simultaneous Spectrophotometric Determination of Fluoxetine and Sertraline

The net analyte signal standard addition method was used for simultaneous spectrophotometric determination of sertraline and fluoxetine in pharmaceutical preparations. The method combines the advantages of the standard addition method with the net analyte signal concept to enable the extraction of information about an analyte from the spectra of multi-component mixtures. This method uses full s...

متن کامل

Wavelength region selection and spectrophotometric simultaneous determination of naphthol isomers based on net analyte signal

Naphthol isomers were simultaneously and spectrophotometrically determined in wastewater, using a model based on net analyte signal (NAS). The calibration method used is a variation of the original hybrid linear analysis method as proposed by Goicoechea and Olivieri (HLA/GO). Owing to spectral interferences, the simultaneous determination of mixtures of naphthol isomers, using a spectrophotomet...

متن کامل

Spectrophotometric Multicomponent Analysis of Ternary and Quaternary Drug Mixtures in Human Urine Samples by Analyzing First-order Data

      A new method was developed for the spectral resolution by further determination of three- and  four-component  mixtures  of  drugs in urine samples through  the complementary application of multivariate curve resolution-alternating least squares with correlation  constraint. In the current study, a simple method was proposed to construct a calibration set for the mixture of drugs in the p...

متن کامل

Standard Addition Connected to Selective Zone Discovering for Quantification in the Unknown Mixtures

Univariate calibration method is a simple, cheap and easy to use procedure in analytical chemistry. A univariate analysis will be successful if a selective signal can be found for the analyte(s). In this work, two simple ways were used to find the selective signals, spectral ratio plot (SRP) and loading plot (LP). Both of them were able to discover the selective regions in the recorded data set...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 126 7  شماره 

صفحات  -

تاریخ انتشار 2001