Design of Single-Phase Power Meter Based Onethernet
نویسندگان
چکیده
According to the related technology about power meter, single-phase power meter based on Ethernet is designed and researched. Single-chip processor MC9S12NE64 is used as system’s CPU and in charge of the system control and information processing. Power measurement chip CS5460A is applied to calculate electrical parameters. EMAC and EPHY modules which are MC9S12NE64’s inter parts are adopted to accomplish Ethernet communication, and how to design Ethernet protocol and data processing are illuminated in detail. The system has realized real-time settlement of electric charge and other network-controlled functions such as power stoppage and supply. It overcomes current problems about electric charge’s disagreement due to offline running of power meter. The power meter is mainly used in the environment where Internet network has been realized, and it is unnecessary to establish wired communication network in addition. Resources of network sharing can be achieved and cost can be saved greatly.
منابع مشابه
A Power Meter Reference Design Based on the ADE7756 Application Note (AN-564)
INTRODUCTION This application note describes a high-accuracy, low-cost power meter based on the ADE7756. The design is for use in the North American 3-wire/single-phase application. This meter may also be used in a single-phase, 2-wire distribution system with a minimal amount of changes. The reference design is comprised of the ADE7756, a microcontroller, LCD display, serial interface, and pow...
متن کاملDesign of A Single-Phase Transformerless Grid-Connected PV Inverter Considering Reduced Leakage Current and LVRT Grid Codes
A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...
متن کاملDesign and Implementation of the Predictive Current Control Strategy in the Single Phase Photovoltaic Grid-Connected Inverter Based on Microcontroller
In this paper, photovoltaic (PV) grid-connected inverter which is the core device in PV grid-connected system has been in depth research.An improved predictive current controller has been developed by the Authors for single-phase grid-connected voltage source inverters (VSI).Based on DSP TMS320LF2407A, a 10 kW single-phase grid-connected inverter has been built in this paper.Thus is aimed at us...
متن کاملThe Design of a New Double Loop Controller For Simultaneous Adjustment of Input and Output Voltages of Single-Phase Grid-Connected Inverter
Although LCL filters are used widely in the grid connected inverters to reduce high-orderharmonics, such a system increases system order and therefore sustainable design of closed-loopcontroller system will be complicated. Recently, the single-loop control strategy has beensuggested for L or LC filter based grid-connected inverters. However, the use of single-loopcontrol directly in LCL filter-...
متن کاملDesign and Simulation of a New DC Power Supply Based on Dual Bridge Matrix Converter
A conventional high power DC power supply systems consist of a three-phase diode rectifier followed by a high frequency converter to supply loads at regulated DC voltage. These rectifiers draw significant harmonic currents from the utility, resulting in poor input power factor. In this paper, a DC power supply based on dual-bridge matrix converter (DBMC) with reduced number of switches is p...
متن کامل