Design of computer-generated hologram with ring focus for nonmechanical corneal trephination with Er:YAG laser in penetrating keratoplasty.
نویسندگان
چکیده
PURPOSE To calculate a beam-shaping optical element for homogeneous intensity distribution within a focal ring to be used in nonmechanical trephination with the Er:YAG laser in penetrating keratoplasty instead of a spot guiding device. METHODS The phase distribution behind a holographic optical element (HOE) k psi(u) can be described by the addition of the hologram phase phiH(u) to the beam phase phiE(u): k psi(u) = phiH(u) + phiE(u), k = 2pi/lambda, where u denotes the coordinates inside the hologram aperture, k an integer, and lambda the laser wavelength. To avoid discontinuous wavefronts leading to speckle noise, a smooth phase function is necessary. After transforming the hologram aperture coordinates into the focal plane x in a focal distance f, psi can be retrieved from the slope equation: inverted delta psi(u) = x(u) - u/f. RESULTS Creating a ring focus can be reduced to an essentially one-dimensional problem by separation of variables due to the symmetry condition. We calculated a computer-generated eight-level phase-only HOE with 4096 x 4096 pixels from a Gaussian-distributed 2.94 Er:YAG laser spot with a beam diameter of 10 mm and a focal distance of 100 mm. Thereby, a ring focus with an inner/outer radius of 7/8 mm can be created. To avoid Poisson's spo, the symmetry of the problem was broken by circular modulation of the phase leading to a spiral-like structure. The calculated efficiency of the HOE relating the energy within the ring to the total energy was 91%. CONCLUSION With an HOE it is possible to redistribute the energy along the desired focal ring. The HOE design can be adapted to the intensity distribution of the impinging laser beam with its characteristic aperture shape. A circular homogeneous corneal trephination depth is possible, because the energy fluctuation from pulse to pulse does not locally affect the ablation process. A ring focus for the Er:YAG laser has the potential to render superfluous a manual beam control via micromanipulator and to allow a more rapid and more regular corneal trephination along aperture masks.
منابع مشابه
Nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty: experimental study on human donor corneas.
OBJECTIVE To assess the alterations in human donor corneal tissue induced by Q-switched erbium (Er):YAG laser corneal trephination. METHODS Thirty human corneoscleral donor buttons unsuitable for transplantation were placed in an artificial chamber on an automated rotation device. Corneas were trephined with a Q-switched Er:YAG laser (wavelength, 2.94 microm; pulse duration, 400 nanoseconds) ...
متن کامل"Orientation teeth" in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 microm Er:YAG v 193 nm ArF excimer laser.
BACKGROUND/AIMS "Orientation teeth" at the donor trephination margin and correspondent "notches" at the host margin facilitate graft orientation and avoid "horizontal torsion" induced by asymmetric suture placement. In this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. METHODS The procedu...
متن کامل“Orientation teeth” in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 μm Er:YAG v 193 nm ArF excimer laser
Background/aims—“Orientation teeth” at the donor trephination margin and correspondent “notches” at the host margin facilitate graft orientation and avoid “horizontal torsion” induced by asymmetric suture placement. In this study the quality and reproducibility of these structures created by non-mechanical laser corneal trephination were compared using two laser emissions. Methods—The procedure...
متن کاملPenetrating Keratoplasty for Keratoconus – Excimer Versus Femtosecond Laser Trephination
BACKGROUND In case of keratoconus, rigid gas-permeable contact lenses as the correction method of first choice allow for a good visual acuity for quite some time. In a severe stage of the disease with major cone-shaped protrusion of the cornea, even specially designed keratoconus contact lenses are no more tolerated. In case of existing contraindications for intrastromal ring segments, corneal ...
متن کاملCorneal lathing using the excimer laser and a computer-controlled positioning system.
PURPOSE To present the excimer laser corneal shaping system (ELCS-S), an add-on device to the Keratom, a commercially available 193-nm excimer laser built by Schwind. METHODS The system is designed for the preparation of donor corneas under sterile conditions using the ultraviolet laser to offer greatest possible flexibility. Lenticules for planolamellar grafting and refractive epikeratoplast...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Japanese journal of ophthalmology
دوره 43 6 شماره
صفحات -
تاریخ انتشار 1999