The effects of positioning of transcatheter aortic valves on fluid dynamics of the aortic root.
نویسندگان
چکیده
Transcatheter aortic valve implantation is a novel treatment for severe aortic valve stenosis. Due to the recent use of this technology and the procedural variability, there is very little data that quantify the hemodynamic consequences of variations in valve placement. Changes in aortic wall stresses and fluid retention in the sinuses of Valsalva can have a significant effect on the clinical response a patient has to the procedure. By comprehensively characterizing complex flow in the sinuses of Valsalva using digital particle image velocimetry and an advanced heart-flow simulator, various positions of a deployed transcatheter valve with respect to a bioprosthetic aortic valve (valve-in-valve) were tested in vitro. Displacements of the transcatheter valve were axial and directed below the simulated native valve annulus. It was determined that for both blood residence time and aortic Reynolds stresses, it is optimal to have the annulus of the transcatheter valve deployed as close to the aortic valve annulus as possible.
منابع مشابه
Transcatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملPatient-Specific Numerical Model of Calcific Aortic Stenosis and Its Treatment by Balloon-Expandable Transcatheter Aortic Valve: Effect of Positioning on the Anchorage
Despite the promising outcomes of transcatheter aortic valve replacement (TAVR), adverse events may occur as a result of suboptimal placement. The aim of this study is to evaluate the effect of various TAVR deployment positions on the risk for intra-procedural migration and of post-procedural paravalvular regurgitation. Finite Element (FE) and Computational Fluid Dynamics (CFD) models are prese...
متن کاملمقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملTranscatheter aortic valves produce unphysiological flows which may contribute to thromboembolic events: An in-vitro study
PURPOSE Transcatheter aortic valve implantation (TAVI) has been associated with large incidence of ischemic events, whose sources are still unclear. In fact, sub-acute complications cannot be directly related to the severity of the calcification in the host tissues, nor with catheter manipulation during the implant. A potential cause could be local flow perturbations introduced by the implantat...
متن کاملThe Current Indications and Options for Aortic Valve Surgery
This review article provides an overview of various aortic valve pathologies and when intervention is indicated with each one. The management options and their controversies are then reviewed, including new technologies, specifically the transcatheter aortic valves and sutureless aortic valves. Aortic root or ascending aorta pathology is out of the scope of this chapter, which focuses on pure a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- ASAIO journal
دوره 60 5 شماره
صفحات -
تاریخ انتشار 2014