A new methodology for inter- and intrafraction plan adaptation for the MR-linac.
نویسندگان
چکیده
The new era of hybrid MRI and linear accelerator machines, including the MR-linac currently being installed in the University Medical Center Utrecht (Utrecht, The Netherlands), will be able to provide the actual anatomy and real-time anatomy changes of the patient's target(s) and organ(s) at risk (OARs) during radiation delivery. In order to be able to take advantage of this input, a new generation of treatment planning systems is needed, that will allow plan adaptation to the latest anatomy state in an online regime. In this paper, we present a treatment planning algorithm for intensity-modulated radiotherapy (IMRT), which is able to compensate for patient anatomy changes. The system consists of an iterative sequencing loop open to anatomy updates and an inter- and intrafraction adaptation scheme that enables convergence to the ideal dose distribution without the need of a final segment weight optimization (SWO). The ability of the system to take into account organ motion and adapt the plan to the latest anatomy state is illustrated using artificial baseline shifts created for three different kidney cases. Firstly, for two kidney cases of different target volumes, we show that the system can account for intrafraction motion, delivering the intended dose to the target with minimal dose deposition to the surroundings compared to conventional plans. Secondly, for a third kidney case we show that our algorithm combined with the interfraction scheme can be used to deliver the prescribed dose while adapting to the changing anatomy during multi-fraction treatments without performing a final SWO.
منابع مشابه
Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy.
PURPOSE The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. METHODS AND MATERIALS In this prospecti...
متن کاملViewRay's MRIdian Linac Selected as MR-Guided Radiotherapy System in Danish Tender
MRIdian enables a fundamental change from conventional radiotherapy by using diagnostic-quality MR imaging and enabling daily on-table treatment plan adaptation. MRIdian also uniquely allows for continuous MR imaging to automatically control beam delivery to account for subtle anatomical changes that may occur during treatment. Combined, these advancements allow clinicians to tailor the dose mo...
متن کاملReal‐time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement
BACKGROUND Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a prelim...
متن کاملTreating locally advanced lung cancer with a 1.5 T MR-Linac – Effects of the magnetic field and irradiation geometry on conventionally fractionated and isotoxic dose-escalated radiotherapy
PURPOSE This study investigates the feasibility and potential benefits of radiotherapy with a 1.5T MR-Linac for locally advanced non-small cell lung cancer (LA NSCLC) patients. MATERIAL AND METHODS Ten patients with LA NSCLC were retrospectively re-planned six times: three treatment plans were created according to a protocol for conventionally fractionated radiotherapy and three treatment pla...
متن کاملMapping of McGraw Cycle to RUP Methodology for Secure Software Developing
Designing a secure software is one of the major phases in developing a robust software. The McGraw life cycle, as one of the well-known software security development approaches, implements different touch points as a collection of software security practices. Each touch point includes explicit instructions for applying security in terms of design, coding, measurement, and maintenance of softwar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 60 19 شماره
صفحات -
تاریخ انتشار 2015