Commercially available blood-gas quality controls compared with tonometered blood.

نویسندگان

  • E T Leary
  • G Graham
  • M A Kenny
چکیده

We compared three commercially supplied blood-gas quality control solutions ("contrIL," "G.A.S.," and "Quantra") and tonometered whole blood under research and service conditions in four hospital laboratories. In some situations Quantra and tonometered blood were comparably sensitive to problems with blood-gas instrument malfunctions (e.g., hydraulics or temperature control) but the aqueous buffer-based materials were less sensitive. Within-day precision for all control materials was similar. The precision of pCO2 determinations in long-term studies was also similar for all control materials, as were pH determinations on commercial controls. For pO2 (especially at O2 < 50 mmHg), sample handling technique influenced the precision and accuracy of Quantra more than the other materials. The variability in pO2 determination with Quantra seems primarily to result from sensitivity in incubation temperature (3% change per degree C at 145 mmHg and 7% change per degree C at 43 mmHg). This study identifies some of the limitations of blood-gas control materials per se and some limitations related to specific blood-gas instruments that affect interpretation of results from them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduced bovine hemoglobin solution evaluated for use as a blood gas quality-control material.

We evaluated a new commercially available partially purified reduced bovine hemoglobin solution (RBHS) and a new tonometer for use in the quality control of blood gas analyzers. RBHS is manufactured in three different formulations, each corresponding to three different bicarbonate-buffering capacities and concentrations of total hemoglobin (ctHb). The P50 for each formulation of RBHS was determ...

متن کامل

Blood gas quality control materials compared to tonometered blood in examining for interinstrument bias in PO2.

Although large differences in mean values and standard deviations of PO2 between models of blood gas instruments have been found in proficiency testing surveys employing commercial ampuled material, it is unknown whether or not equivalent differences would be found between instruments if a primary standard (tonometered fresh human blood) were used instead of ampules (secondary control specimens...

متن کامل

Long-term reproducibility of a new pH/blood-gas quality-control system compared to two other procedures.

The long-term precision and stability of a new quality-control system for blood pH and gas measurements are compared to that of tonometered bicarbonate solutions and serum-based preparations. The new system, consisting of gas-equilibrated bicarbonate solutions in glass ampuls, is shown to be as stable as the serum-based preparation, and as reproducible as either of the other methods. The new sy...

متن کامل

Assessment of recently developed blood gas analysers: a multicentre evaluation

Providing guidelines for testing expected inaccuracy and imprecision is still a matter under debate. The Expert Panel of the French Society of Clinical Chemistry has developed a protocol, which was based on a comparative multi-centre evaluation of four instruments: the Ciba-Corning 278, the Instrumentation Laboratory 1306, the Nova SP 5 and the ABL 330. The purpose was to evaluate the analytica...

متن کامل

Proficiency testing for blood-gas quality control.

We have conducted a voluntary, community blood-gas proficiency testing program, with use of tonometered human blood, for 32 analyzers located in 16 laboratories. Instruments initially showed inaccuracies as large as -30.8 to +17.3% for po(2), and -14.0 to +42.9% for pco(2), but inaccuracy and imprecision decreased in most laboratories during the program. For a typical 15-week period, mean group...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 9  شماره 

صفحات  -

تاریخ انتشار 1980