Water Adsorption on Lubricated a-CHx in Humid Environments

نویسندگان

  • Nisha Shukla
  • Xiaoding Ma
  • Jing Gui
  • Andrew J. Gellman
چکیده

Humidity influences the tribological performance of the head-disk interface in magnetic data storage devices. In this work a quartz crystal microbalance was used to measure the uptake of water on amorphous hydrogenated carbon (a-CHx) films at room temperature and pressures of water corresponding to relative humidities of 25%: These experiments have used a-CHx films of varying thickness with and without lubricant. The lubricants used included Fomblin Z-03, Z-disoc, and Z-tetraol deposited on the surfaces of a-CHx films of various thickness. The amount of water adsorbed on the unlubricated a-CHx films is roughly independent of a-CHx film thickness. The presence of the lubricant reduces the amount of adsorbed water; however, the amount of water adsorbed in the presence of a lubricant does not depend significantly on the type of lubricant. These observations imply that water is adsorbed on the surfaces of the lubricant or the a-CHx film rather than being absorbed in their bulk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Humidity on Lubricated Carbon Overcoats

An apparatus has been designed and built to measure the adsorption of contaminants on the surfaces of lubricated carbon overcoats such as those used on magnetic data storage media. The device is based on a quartz crystal microbalance housed in a high vacuum chamber and can be used to make rapid measurements of both the amounts and the rates of contaminant adsorption from the gas phase during ex...

متن کامل

Water adsorption on lubricated fullerene-like CNx films

Humidity influences the tribological performance of the head–disk interface in magnetic data storage devices. In this work we compare the uptake of water of amorphous hydrogenated carbon (a-CHy) and carbon nitride (a-CNx) films, widely used as protective overcoats in computer disk drive systems, with two types of amorphous non-hydrogenated carbon (a-C and a-Csp2) films, and fullerene-like carbo...

متن کامل

Kinetic Stability of MOF-5 in Humid Environments: Impact of Powder Densification, Humidity Level, and Exposure Time.

Metal-organic frameworks (MOFs) are an emerging class of microporous, crystalline materials with potential applications in the capture, storage, and separation of gases. Of the many known MOFs, MOF-5 has attracted considerable attention because of its ability to store gaseous fuels at low pressure with high densities. Nevertheless, MOF-5 and several other MOFs exhibit limited stability upon exp...

متن کامل

Effect of Humid Aging on the Oxygen Adsorption in SnO2 Gas Sensors

To investigate the effect of aging at 580 °C in wet air (humid aging) on the oxygen adsorption on the surface of SnO₂ particles, the electric properties and the sensor response to hydrogen in dry and humid atmospheres for SnO₂ resistive-type gas sensors were evaluated. The electric resistance in dry and wet atmospheres at 350 °C was strongly increased by humid aging. From the results of oxygen ...

متن کامل

Adsorption of fluorinated ethers and alcohols on fresh and oxidized carbon overcoats for magnetic data storage.

Temperature programmed desorption has been used to study the desorption kinetics and desorption energies of perfluorodiethylether, (CF3CF2)2O, and 2,2,2-trifluoroethanol, CF3CH2OH, adsorbed on fresh and oxidized hydrogenated amorphous carbon (a-CHx) films. (CF3CF2)2O and CF3CH2OH serve as models for the ether backbone and hydroxyl end-groups of Fomblin Zdol, the lubricant most commonly used to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003